(usa installatons only)

The Quadra-Fire Bodega Bay ACT Wood Stove Insert is listed to UL 1482 Standard and approved for installation into listed factory built zero clearance fireplaces listed to UL 127 conforming to the following specifications and instructions:

The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chim- ney liner meeting type H.T. requirements (2100°F) per UL 1777. The air flow of the factory-built zero-clearance fire- place system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air- cooled chimney system.

NOTE: Refer to chimney liner manufacturer for rec- ommendations on supporting the liner.

Minimum Width of cavity opening:

30 in.

Minimum Height:

21 in.

Minimum Depth from front to rear:

16-1/4 in.

Mantel

Listed Liner

The following modifications of factory built fireplaces are permissible: 1) removal of damper; 2) removal of smoke shelf or baffle; 3) removal of ember catches; 4) removal of fire grate; 5) removal of viewing screen/curtain; and, 6) removal of doors.

NOTE: Installation into fireplaces without a permit will void the listing.

The factory built chimney must be listed per UL 127 and meet the type HT requirements of UL 103. Factory built fireplace chimneys tested to UL 127-1998, may be at the fireplace manufacturer’s option, tested to the same criteria as UL 103 HT requirements. If the chimney is not listed as meeting HT requirements, or if the factory built fire- place was tested prior to 1998, a full height listed chimney liner must be installed from the appliance flue collar to the chimney top. The liner must meet type HT requirements (2100ºF) per UL 1777.

The liner must be securely attached to the insert flue collar and the chimney top. To prevent room air passage to the chimney cavity of the fireplace, seal either the damper area around the chimney liner with high temperature sealant or the fireplace front with fiberglass batting.

The fireplace must not be altered, except that the damper may be removed to accommodate a direct-connect starter pipe or chimney liner, and external trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed.

SEAL DAMPER AREA OR FACE SEAL

Figure 10A - Installation Into A Factory-Built

Zero Clearance Fireplace

The permanent metal warning label provided must be attached to the back of the fireplace, with screws or nails, stating that the fireplace may have been altered to accom- modate the insert, and must be returned to original condition for use as a conventional fireplace.

If the hearth extension is lower than the fireplace opening, the portion of the insert extending onto the hearth must be supported. Manufacturer designed adjustable support kit can be ordered from your dealer. (See page 14).

Final approval of this installation type is contingent upon the authority having jurisdiction.

WARNING

Fire Risk.

When lining air-cooled factory-built chimneys:.

Run chimney liner approved to UL 1777 Type HT requirements (2100 degrees F)

Re-install original factory built chimney cap

ONLY

DO NOT block cooling air openings in chimney

Blocking cooling air will overheat the chimney

Page 10

435-1320B

August 20, 2008

Image 10
Contents Advanced Combustion Technology ACT Installation and Operation ModelImportant Safety Notes BodbayLocation On Beaded Chain, Left Side Behind Outer Skin Sample of Serial Number / Safety LabelBodega BAY Wood Insert Test Lab Report No Manufactured DateTable of Contents Front View TOP ViewSide View Clearances to CombustiblesListings Installation recommendationsChimney HEIGHT/DRAFT General Installation Procedure Alternate Floor Protection WorksheetImney Height Chimney RequirementsOvalizing Round Stainless Steel Liners Chimney TOP ViewInstallations Into Zero Clearance Fireplaces in Mobile Homes Installation Options Masonry Fireplace Using DIRECT-CONNECT MethodUsa installatons only Factory built zero clearance fireplaceLeveling Bolts and sheet metal shims Installation in CanadaMasonry and HEAT-CIRCULATING Outside AIR Installation Securing Liner to Chimney RingDoor Latch Adjustment Door Handle AssemblyPanel and Gold or Nickel Trim SET Blower Cord Location & Blower Control BOX with Switch Zero Clearance Adjustable Trim SUPPORT, 2 to Building a Fire OverfiringWood Selection and Storage Fan operating instructions Bodega BAY Wood Insert Operating TipsASH Removal Air quality and your Quadra-Fire Insert Story of the Three Burning StagesMaintenance Brick replacement instructions Part Baffle Removal & InstallationExploded View Ceramic BlanketService Parts AccessoriesAppliance Lifetime Warranty Warranty PolicyBodega Bay Wood Insert