Generac Power Systems 004373-6, 004626-5 owner manual CHASSIS, Universal

Page 39

Section 8 — Exploded Views and Parts Lists

(Model No. 0046262, 0046263 & 0046264) Guardian Liquid-cooled 40 kW Generator Control Panel – Drawing No. 0D6978-C

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D7397

1

PNL BTM & BACK CNTL PNL 04626

2

0D1521A

1

CONTROL PANEL FRONT W/ SILK

 

 

 

SCREEN

3

0D1522

1

PANEL SIDE COVER CONTROL

 

 

 

PANEL

4

067680

1

ASSY VOLTAGE REGULATOR 60HZ

5

0C8243

1

WASHER LOCK HDP DEUTSCH

6

0C8244

1

NUT, HDP DEUTSCH

7

0A6321

1

PANEL LEFT SIDE E

8

048467

1

CIRCT BRK 7 X 1 ETA 46-500-P

9

057907

1

RES WW LUG 10R 10% 25W

10

064008

1

COVER CON PNL TOP (NOT SHOWN)

11

0E3550

1

CHASSIS, UNIVERSAL

12

055444

1

HEATSINK

13

030468

1

WASHER STEP NYLON .20

14

049939

1

RECTIFIER MSC 12A 600V 1N1206R

15

070370

1

WASHER MICA .203

16

022158

1

NUT HEX #10-32 STEEL

17

023762

1

WASHER SHAKEPROOF EXT #10

 

 

 

STL

18

023897

15

WASHER FLAT #10 ZINC

19

076009A

1

PP LOGIC ASM 50/60HZ

20

040213

4

PCB SUPPORT SNAP-IN 1/4"

21

0A3394

1

GROMMET 3/4 X 5/32 X 5/16

22

082573

1

SWITCH ROCKER DPST 125V SPD

23

076020

1

SWITCH TOG DPDT 15/10 SP

24

032300

1

HOLDER FUSE

25

022676

1

FUSE 15A X AGC15

26

064009

1

LIGHT 12VDC .02A LED RED PILOT

27

061945

1

SWITCH SELECTOR 6A AMP/V

28

076037

1

VOLTMETER DC 8-18V

29

070081

1

HOURMETER

30

070043

1

VOLTMETER AC 0-300

31

070045

1

AMMETER AC 0-200

32

070042

1

FREQUENCY METER 240V 55-65HZ

ITEM

PART NO.

QTY.

DESCRIPTION

33

081988

1

DECAL EXERCISE INFO

34

0C1229

1

DECAL CUST CONN BOX

35

0D3440

1

CONTROLLER, B-C #DPG-2103

36

0A3968

1

CAPACITOR FILTER ASY

37

048766

REF

BLOCK TERM 20A 2 X 6 X 1100V

38

0A1441B

1

COVER PLATE AVR

39

083264

1

TFMR ASM,CMA 240/12V

40

0A1441C

1

COVER PLATE EGOV

41

057335

REF

BLOCK TERM 20A 20 X 6 X 1100V

42

076061

1

DECAL TERM. STRIP

43

029333

6

TIE WRAP 7.4" X .19" NATL UL

44

040479

4

VIB MNT 1.0 X 1.0 X 1/4-20

45

022507

4

SCREW HHC 1/4-20 X 1/2 G5

46

022127

4

NUT HEX 1/4-20 STEEL

47

022097

4

WASHER LOCK M6-1/4

48

033121

14

SCREW HHC #10-32 X 1/2

49

022152

14

WASHER LOCK #10

50

036902

4

SCREW PPHM #6-32 X 1/2

51

022155

6

WASHER LOCK #6

52

022985

8

WASHER FLAT #6 ZINC

53

036918

8

SCREW PPHM #8-32 X 1/2

54

022264

8

WASHER LOCK M4

55

038150

8

WASHER FLAT #8 ZINC

56

022471

8

NUT HEX #8-32 STEEL

57

022188

6

NUT HEX #6-32 STEEL

58

0C2428

8

SCREW PHTT #6-32 X 1/2 ZYC

59

0C2323

4

SCREW PHTT #6-32 X 5/8 ZYC

60

0A2284

4

SCREW SWAGE 8-32 X 1/2 Z/YC

61

0C1127

1

DECAL AVR COVER

62*

0D5324

4

FUSE & HOLDER LITTEL 7.5A

63*

0A9611

1

FUSE 7.5AXBK/AGC7.5NX W/22670

64

074908

4

SCREW HHTT M5-0.8 X 10 BP

65

0E3783

1

DECAL, WARNING REMOVE FUSE

* PART OF CONTROL PANEL WIRE HARNESS

Generac® Power Systems, Inc. 37

Image 39
Contents Liquid-cooled, Prepackaged Standby Generators Models Authorized Dealer Location IntroductionInstallation Diagram General Hazards Electrical Hazards Generator AC Connection Systems Prepackaged Transfer SwitchUNPACKING/INSPECTION GeneratorSpecifications Main Circuit BreakerEngine Protective Devices Fuel Requirements Recommendations ‹ 1.8.2 Generator and Load Compatibility‹ 1.9.1 Conversion to LP GAS Vapor Emissions Control System Coolant‹ 1.12.1 AIR Fuel Ratio Controller Other Published Standards Standby Generator InstallationBasic Standby Electric System Nfpa StandardsGrounding the Generator Transfer Switch Start Signal Connections‹ 2.6.1 PRE-PACKAGED Type Switch Method‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP Using the AUTO/OFF/MANUAL Switch Sequence of Automatic Operation Engine Heater‹ 3.2.3 Manual Position Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.1 Engine OIL Recommendations Changing the Engine AIR Cleaner‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine OIL and FilterCooling System Battery Maintenance‹ 4.5.1 Battery Replacement Spark PlugsEngine Coolant Miscellaneous MaintenanceOverload Protection for DC FuseOUT of Service Procedure ‹ 4.11.1 Removal from Service‹ 4.11.2 Return to Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideInstallation Diagram TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No Drawing No KW Generators No D6975 EC1 ACT 12 19 11 3529 QTY Description ONE Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists CHASSIS, Universal Exploded Views and Parts Lists QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists Mount Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor To Valve Cover To Intake Manifold Support Solenoid NAT GAS Attach to FAN Scroll Elbow 90D 3/4NPT Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

004373-6, 004626-5 specifications

Generac Power Systems has established itself as a leader in the field of backup and portable power solutions, and their models 004626-5 and 004373-6 are prime examples of their dedication to innovation and reliability. These models are designed to cater to a variety of power needs, making them essential assets for homeowners and businesses alike.

The 004626-5 is a robust home standby generator, renowned for its powerful performance and automatic transfer switch capabilities. This model features Generac's G-Force engine, which is specifically engineered for high performance and longevity, ensuring that it can handle the demands of powering a home during outages. It boasts a multi-language LCD display that provides real-time system status updates, allowing users to monitor performance with ease. Additionally, the 004626-5 is equipped with an integrated wi-fi system, enabling remote monitoring through the Mobile Link app. This feature gives users the convenience of checking their generator's status from anywhere, ensuring peace of mind.

On the other hand, the 004373-6 is a portable generator designed for versatility and convenience. This model is lightweight and easily transportable, making it ideal for outdoor activities, job sites, or emergency power supply during outages. Powered by a reliable OHV engine, the 004373-6 delivers impressive power output while maintaining fuel efficiency. Its ergonomic design includes a transport handle and never-flat wheels, allowing for easy maneuverability. The model also features Generac’s PowerRush technology, which provides over 50% more starting capacity, making it capable of handling larger appliances with ease.

Both models are designed with safety features in mind. The 004626-5 comes with a durable weather-resistant enclosure, protecting it from the elements, while the 004373-6 includes a low-oil shutdown feature to prevent engine damage.

In summary, Generac Power Systems continues to set the benchmark for reliability and innovation in power solutions with models 004626-5 and 004373-6. With their advanced technologies, user-friendly features, and unparalleled performance, these generators are engineered to provide power when it’s needed most, ensuring a seamless transition during outages and enhancing convenience for users across various settings.