Generac Power Systems 004373-6, 004626-5 owner manual Muffler Catalyst 4.3L

Page 57

Section 8 — Exploded Views and Parts Lists

(Model No. 0046262, 0046263 & 0046264) Guardian Liquid-cooled 40 kW Generators Exhaust – Drawing No. 0E1347-A

ITEM

PART NO.

QTY.

DESCRIPTION

1

059902A

1

CAP RAIN 2.50 / 2.69

2

0C9641

1

TUBE STRAIGHT 'A' GROUP

3

0D4208

1

MUFFLER CATALYST 4.3L

4

0D5061

4

MOUNTING BAND A-GRP CATALYST

5

0C4126

2

BRACKET MUFFLER MOUNTING

6

0D5787

1

TUBE ELBOW 90 DEG 2.5"

7

0A5215B

2

PIPE FLEX 2.5"

8

0E0699

1

TUBE, CROSS OVER

9

0E0698

1

TUBE, 90 ELBOW

10

0C4170

2

BRACKET EXHAUST SHIELD

11

0C4305

1

SHIELD A-GRP HEAT

12

0C2454

2

SCREW TH-FRM M6-1 X 16 N WA Z/JS

13

0C3433A

4

CLAMP BAND 2.5"

14

022129

16

WASHER LOCK M8-5/16

15

022145

20

WASHER FLAT 5/16 ZINC

16

045771

4

NUT HEX M8-1.25 G8 YEL CHR

18

042907

16

SCREW HHC M8-1.25 X 16 G8.8

19

080762

6

BOLT U 3/8-16 X 2.62

20

022237

12

WASHER LOCK 3/8

21

022241

12

NUT HEX 3/8-16 STEEL

22

0E0701

1

SHIELD, CROSSOVER HEAT

23

0E0700

1

SHIELD, EXHAUST HEAT

24

077879

1

HOSE VACUUM 5/32 (36"LG)

25

0D4221

1

KIT AIR/FUEL RATIO CONTROLLER

26

0D4512

1

BRACKET AIR/FUEL CONTROLLER

27

043116

2

SCREW HHC M6-1.0 X 12 G8.8

28

022471

5

NUT HEX #8-32 STEEL

29

022264

5

WASHER LOCK #8-M4

30

038150

8

WASHER FLAT #8 ZINC

31

036918

5

SCREW PPHM #8-32 X 1/2

32

049811

2

WASHER FLAT M6

33

022097

2

WASHER LOCK M6-1/4

34

049813

2

NUT HEX M6 X 1.0 G8 YEL CHR

35

0D8780

1

DECAL IMPORTANT EXHAUST EMISSION INFO

36

022131

8

WASHER FLAT 3/8-M10 ZINC

*NOTE: COMPONENT INSTALLED AT WAUKESHA FACILITY

Generac® Power Systems, Inc. 55

Image 57
Contents Liquid-cooled, Prepackaged Standby Generators Models Authorized Dealer Location IntroductionInstallation Diagram General Hazards Electrical Hazards UNPACKING/INSPECTION Prepackaged Transfer SwitchGenerator Generator AC Connection SystemsSpecifications Main Circuit BreakerEngine Protective Devices Fuel Requirements Recommendations ‹ 1.8.2 Generator and Load Compatibility‹ 1.9.1 Conversion to LP GAS Vapor Emissions Control System Coolant‹ 1.12.1 AIR Fuel Ratio Controller Basic Standby Electric System Standby Generator InstallationNfpa Standards Other Published Standards‹ 2.6.1 PRE-PACKAGED Type Switch Transfer Switch Start Signal ConnectionsMethod Grounding the Generator‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP Using the AUTO/OFF/MANUAL Switch Sequence of Automatic Operation Engine Heater‹ 3.2.3 Manual Position Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine AIR CleanerChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL Recommendations‹ 4.5.1 Battery Replacement Battery MaintenanceSpark Plugs Cooling SystemOverload Protection for Miscellaneous MaintenanceDC Fuse Engine CoolantOUT of Service Procedure ‹ 4.11.1 Removal from Service‹ 4.11.2 Return to Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideInstallation Diagram TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No Drawing No KW Generators No D6975 EC1 ACT 12 19 11 3529 QTY Description ONE Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists CHASSIS, Universal Exploded Views and Parts Lists QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists Mount Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor To Valve Cover To Intake Manifold Support Solenoid NAT GAS Attach to FAN Scroll Elbow 90D 3/4NPT Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

004373-6, 004626-5 specifications

Generac Power Systems has established itself as a leader in the field of backup and portable power solutions, and their models 004626-5 and 004373-6 are prime examples of their dedication to innovation and reliability. These models are designed to cater to a variety of power needs, making them essential assets for homeowners and businesses alike.

The 004626-5 is a robust home standby generator, renowned for its powerful performance and automatic transfer switch capabilities. This model features Generac's G-Force engine, which is specifically engineered for high performance and longevity, ensuring that it can handle the demands of powering a home during outages. It boasts a multi-language LCD display that provides real-time system status updates, allowing users to monitor performance with ease. Additionally, the 004626-5 is equipped with an integrated wi-fi system, enabling remote monitoring through the Mobile Link app. This feature gives users the convenience of checking their generator's status from anywhere, ensuring peace of mind.

On the other hand, the 004373-6 is a portable generator designed for versatility and convenience. This model is lightweight and easily transportable, making it ideal for outdoor activities, job sites, or emergency power supply during outages. Powered by a reliable OHV engine, the 004373-6 delivers impressive power output while maintaining fuel efficiency. Its ergonomic design includes a transport handle and never-flat wheels, allowing for easy maneuverability. The model also features Generac’s PowerRush technology, which provides over 50% more starting capacity, making it capable of handling larger appliances with ease.

Both models are designed with safety features in mind. The 004626-5 comes with a durable weather-resistant enclosure, protecting it from the elements, while the 004373-6 includes a low-oil shutdown feature to prevent engine damage.

In summary, Generac Power Systems continues to set the benchmark for reliability and innovation in power solutions with models 004626-5 and 004373-6. With their advanced technologies, user-friendly features, and unparalleled performance, these generators are engineered to provide power when it’s needed most, ensuring a seamless transition during outages and enhancing convenience for users across various settings.