Generac Power Systems 004626-5, 004373-6 DIA. Clamp Assembly 2 Compartment To Engine Front

Page 50

Section 8 — Exploded Views and Parts Lists

(Model No. 0043733, 0043734 & 0043735) Guardian Liquid-cooled 40 kW Generators 4.3L Exhaust – Drawing No. 0E0704-A

20

19

1

21

21

20

2.5" DIA. CLAMP ASSEMBLY 2 24

 

21

23

 

 

19

 

20

 

19

 

 

 

24

 

6

 

 

 

 

 

 

 

22

 

 

 

19

 

 

 

 

 

 

19

 

 

 

 

9

 

19

 

 

 

 

 

19

 

 

 

 

 

 

 

19

3

13

19

 

 

 

 

 

8

18

 

 

7

16

 

14

 

18

 

 

15

 

 

 

4

14

13

 

 

 

13

 

 

5

15

 

 

 

 

10

 

 

 

TO

 

 

11

 

 

COMPARTMENT

 

 

 

 

 

 

 

TO ENGINE

FRONT

 

 

 

TO ENGINE

15

12

5

14

4

18

 

 

 

 

10

ITEM

PART NO.

QTY.

DESCRIPTION

 

ITEM

PART NO.

QTY.

DESCRIPTION

1

059902A

1

CAP RAIN 2.50 / 2.69

13

0C3433A

4

CLAMP BAND 2.5"

2

0C9641

1

TUBE STRAIGHT 'A' GROUP

14

022129

12

WASHER LOCK M8-5/16

3

0C9650

1

MUFFLER 2-1/2" INLET/OUTLET

15

022145

12

WASHER FLAT 5/16 ZINC

4

0C4114A

2

CLAMP BAND MUFFLER 6.5"

16

0C9748

1

PLUG M18-1.5

5

0C4126

2

BRACKET MUFFLER MOUNTING

18

042907

12

SCREW HHC M8-1.25 X 16 G8.8

6

0D5787

1

TUBE ELBOW 90 DEG 2.5"

19

080762

6

BOLT U 3/8-16 X 2.62

7

0A5215B

2

PIPE FLEX 2.5"

20

022237

12

WASHER LOCK 3/8

8

0E0699

1

TUBE, CROSS OVER

21

022241

12

NUT HEX 3/8-16 STEEL

9

0E0698

1

TUBE, 90 ELBOW

22

0E0701

1

SHIELD, CROSSOVER HEAT

10

0C4170

2

BRACKET EXHAUST SHIELD

23

0E0700

1

SHIELD, EXHAUST HEAT

11

0C4305

1

SHIELD A-GRP HEAT

24

022131

8

WASHER FLAT 3/8-M10 ZINC

12

0C2454

2

SCREW TH-FRM M6-1 X 16 N WA

 

 

 

 

 

 

 

 

Z/JS

 

 

 

 

 

48 Generac® Power Systems, Inc.

Image 50
Contents Liquid-cooled, Prepackaged Standby Generators Models Introduction Authorized Dealer LocationInstallation Diagram General Hazards Electrical Hazards Generator Prepackaged Transfer SwitchUNPACKING/INSPECTION Generator AC Connection SystemsEngine Protective Devices SpecificationsMain Circuit Breaker ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements Recommendations‹ 1.8.2 Generator and Load Compatibility ‹ 1.12.1 AIR Fuel Ratio Controller Emissions Control SystemCoolant Nfpa Standards Standby Generator InstallationBasic Standby Electric System Other Published StandardsMethod Transfer Switch Start Signal Connections‹ 2.6.1 PRE-PACKAGED Type Switch Grounding the GeneratorBattery Installation ‹ 2.7.1 Vented BatteriesPreparation Before START-UP Using the AUTO/OFF/MANUAL Switch ‹ 3.2.3 Manual Position Sequence of Automatic OperationEngine Heater Weekly Exercise Cycle Checking the Engine OIL LevelChanging the Engine OIL and Filter Changing the Engine AIR Cleaner‹ 4.2.2 OIL and Filter Change Procedure ‹ 4.2.1 Engine OIL RecommendationsSpark Plugs Battery Maintenance‹ 4.5.1 Battery Replacement Cooling SystemDC Fuse Miscellaneous MaintenanceOverload Protection for Engine Coolant‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service Service Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionInstallation Diagram TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No Drawing No KW Generators No D6975 EC1 ACT 12 19 11 3529 QTY Description ONE Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists CHASSIS, Universal Exploded Views and Parts Lists QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists Mount Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor To Valve Cover To Intake Manifold Support Solenoid NAT GAS Attach to FAN Scroll Elbow 90D 3/4NPT Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule

004373-6, 004626-5 specifications

Generac Power Systems has established itself as a leader in the field of backup and portable power solutions, and their models 004626-5 and 004373-6 are prime examples of their dedication to innovation and reliability. These models are designed to cater to a variety of power needs, making them essential assets for homeowners and businesses alike.

The 004626-5 is a robust home standby generator, renowned for its powerful performance and automatic transfer switch capabilities. This model features Generac's G-Force engine, which is specifically engineered for high performance and longevity, ensuring that it can handle the demands of powering a home during outages. It boasts a multi-language LCD display that provides real-time system status updates, allowing users to monitor performance with ease. Additionally, the 004626-5 is equipped with an integrated wi-fi system, enabling remote monitoring through the Mobile Link app. This feature gives users the convenience of checking their generator's status from anywhere, ensuring peace of mind.

On the other hand, the 004373-6 is a portable generator designed for versatility and convenience. This model is lightweight and easily transportable, making it ideal for outdoor activities, job sites, or emergency power supply during outages. Powered by a reliable OHV engine, the 004373-6 delivers impressive power output while maintaining fuel efficiency. Its ergonomic design includes a transport handle and never-flat wheels, allowing for easy maneuverability. The model also features Generac’s PowerRush technology, which provides over 50% more starting capacity, making it capable of handling larger appliances with ease.

Both models are designed with safety features in mind. The 004626-5 comes with a durable weather-resistant enclosure, protecting it from the elements, while the 004373-6 includes a low-oil shutdown feature to prevent engine damage.

In summary, Generac Power Systems continues to set the benchmark for reliability and innovation in power solutions with models 004626-5 and 004373-6. With their advanced technologies, user-friendly features, and unparalleled performance, these generators are engineered to provide power when it’s needed most, ensuring a seamless transition during outages and enhancing convenience for users across various settings.