Generac Power Systems 004373-6, 004626-5 owner manual Qty

Page 41

 

 

 

 

Section 8 — Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

Guardian Liquid-cooled 40 kW Generators

 

 

 

 

 

 

Connection Box – Drawing No. 0E6892-A

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

1

0E6353

1

LOWER PANEL 15

 

 

2

0D5489

1

COVER LOWER CONNECTION BOX

 

 

3

0E6427

1

PLATE GLAND

 

 

4

023484N

2

BUSHING SNAP SB-2.5-31

 

 

5

0E6454

1

BRACKET NEUTRAL

 

 

6

056739

1

RELAY SOLENOID 12VDC PNL MNT

 

 

7

0C2454

2

SCREW THF M6-1X16 N WA Z/JS

 

 

8

051715

2

NUT HEX M4-0.7 G8 YEL CHR

 

 

9

0D3388

1

DECAL REMOTE START CONNECTION

 

 

10

058710

2

TRANSFORMER 200A TO 5A 5VA

 

 

11

0D5492

1

HARNESS LOWER PANEL 4.3L GRDN

 

 

 

 

(048766)

REF.

BLOCK TERM 20A 2 X 6 X 1100V

 

 

12

022985

2

WASHER FLAT #6 ZINC

 

 

13

0E6689

1

COVER LOWER

 

 

14

022264

2

WASHER LOCK M4

 

 

15

052813

2

SCREW HHC M4-0.7 X 20 G8.8

 

 

16

039253

4

SCREW HHC M8-1.25 X 20 G8.8

 

 

17

022145

6

WASHER FLAT 5/16 ZINC

 

 

18

0D5840

1

DECAL CUSTOMER CONNECTN FOR TS

 

 

19

022129

5

WASHER LOCK M8-5/16

 

 

20

045771

5

NUT HEX M8-1.25 G8 YEL CHR

 

 

21

022287

28

SCREW HHC 1/4-20 X 3/4 G5

 

 

22

022473

36

WASHER FLAT 1/4 ZINC

 

 

23

022097

34

WASHER LOCK M6-1/4

 

 

24

022127

6

NUT HEX 1/4-20 STEEL

 

 

25

0E4458

1

CB 0200A 240V 2P S QJ22B200HL

 

 

26

0E5586

1

PLATE CB MOUNT S (QJ 2P) 390S

 

 

27

0E5587

1

COVER TERMINALS S (QJ 2P)

 

 

28

022237

4

WASHER LOCK 3/8

 

 

29

022241

2

NUT HEX 3/8-16 STEEL

 

 

30

081320

2

SCREW SHC 1/4-20 X 4.5 G8.8 NZ

 

 

31

048527

2

SCREW SHC 3/8-16 X 3/4 G5

 

 

32

0D5464B

1

NEUTRAL BLOCK 390/200-400A

 

 

33

057073

2

JUNCTION BLOCK 3/8-16

 

 

34

0C2266

4

SCREW PHTT M5-0.8 X 16 ZYC

 

 

Generac® Power Systems, Inc. 39

Image 41
Contents Liquid-cooled, Prepackaged Standby Generators Models Authorized Dealer Location IntroductionInstallation Diagram General Hazards Electrical Hazards UNPACKING/INSPECTION Prepackaged Transfer SwitchGenerator Generator AC Connection SystemsEngine Protective Devices SpecificationsMain Circuit Breaker ‹ 1.9.1 Conversion to LP GAS Vapor Fuel Requirements Recommendations‹ 1.8.2 Generator and Load Compatibility ‹ 1.12.1 AIR Fuel Ratio Controller Emissions Control SystemCoolant Basic Standby Electric System Standby Generator InstallationNfpa Standards Other Published Standards‹ 2.6.1 PRE-PACKAGED Type Switch Transfer Switch Start Signal ConnectionsMethod Grounding the Generator‹ 2.7.1 Vented Batteries Battery InstallationPreparation Before START-UP Using the AUTO/OFF/MANUAL Switch ‹ 3.2.3 Manual Position Sequence of Automatic OperationEngine Heater Checking the Engine OIL Level Weekly Exercise Cycle‹ 4.2.2 OIL and Filter Change Procedure Changing the Engine AIR CleanerChanging the Engine OIL and Filter ‹ 4.2.1 Engine OIL Recommendations‹ 4.5.1 Battery Replacement Battery MaintenanceSpark Plugs Cooling SystemOverload Protection for Miscellaneous MaintenanceDC Fuse Engine Coolant‹ 4.11.2 Return to Service OUT of Service Procedure‹ 4.11.1 Removal from Service SYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideInstallation Diagram TS1 Generator D4992-A Guardian Liquid- Panel 4.3L Drawing No Section Wiring Diagram Control Panel Model No Drawing No KW Generators No D6975 EC1 ACT 12 19 11 3529 QTY Description ONE Assembly M6 Hinge Panel Face Panel BTM & Back Control Exploded Views and Parts Lists CHASSIS, Universal Exploded Views and Parts Lists QTY To Engine Flywheel Washer Lock M12 Exploded Views and Parts Lists Engine 4.3L GM Exploded Views and Parts Lists Mount Engine R & L KIT Radiator Copper Brass DIA. Clamp Assembly 2 Compartment To Engine Front NUT Wing 1/4-20 Nylk To Stepper Motor To Valve Cover To Intake Manifold Support Solenoid NAT GAS Attach to FAN Scroll Elbow 90D 3/4NPT Exploded Views and Parts Lists Muffler Catalyst 4.3L Assembly Motor Stepper To Thermostat Housing Guardian Liquid-cooled 40 kW Generators Guardian Liquid-cooled 40 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

004373-6, 004626-5 specifications

Generac Power Systems has established itself as a leader in the field of backup and portable power solutions, and their models 004626-5 and 004373-6 are prime examples of their dedication to innovation and reliability. These models are designed to cater to a variety of power needs, making them essential assets for homeowners and businesses alike.

The 004626-5 is a robust home standby generator, renowned for its powerful performance and automatic transfer switch capabilities. This model features Generac's G-Force engine, which is specifically engineered for high performance and longevity, ensuring that it can handle the demands of powering a home during outages. It boasts a multi-language LCD display that provides real-time system status updates, allowing users to monitor performance with ease. Additionally, the 004626-5 is equipped with an integrated wi-fi system, enabling remote monitoring through the Mobile Link app. This feature gives users the convenience of checking their generator's status from anywhere, ensuring peace of mind.

On the other hand, the 004373-6 is a portable generator designed for versatility and convenience. This model is lightweight and easily transportable, making it ideal for outdoor activities, job sites, or emergency power supply during outages. Powered by a reliable OHV engine, the 004373-6 delivers impressive power output while maintaining fuel efficiency. Its ergonomic design includes a transport handle and never-flat wheels, allowing for easy maneuverability. The model also features Generac’s PowerRush technology, which provides over 50% more starting capacity, making it capable of handling larger appliances with ease.

Both models are designed with safety features in mind. The 004626-5 comes with a durable weather-resistant enclosure, protecting it from the elements, while the 004373-6 includes a low-oil shutdown feature to prevent engine damage.

In summary, Generac Power Systems continues to set the benchmark for reliability and innovation in power solutions with models 004626-5 and 004373-6. With their advanced technologies, user-friendly features, and unparalleled performance, these generators are engineered to provide power when it’s needed most, ensuring a seamless transition during outages and enhancing convenience for users across various settings.