Generac Power Systems 2.4L owner manual C2 Units

Page 67

1.)

C2 UNITS

 

 

A

0F9832

1

SHIELD CONN BOX C2

 

0F9832GGS0R

1

SHIELD CONTROL STAND C2

B

0C2454

3

SCREW THF M6-1 X 16 N WA Z/JS

2.)

C3 UNITS

 

 

A

0F9832B

1

SHIELD CONTROL STAND C3

 

0F9832KGS0R

1

SHIELD CONTROL STAND C3

B

0C2454

3

SCREW THF M6-1 X 16 N WA Z/JS

3.)

C4 UNITS

 

 

A

0F9832A

1

SHIELD CONTROL STAND C4

B

0C2454

2

SCREW THF M6-1 X 16 N WA Z/JS

4.)

C5 UNITS

 

 

A

0F9832C

1

SHIELD CONTROL STAND C5

 

0F9832D

1

SHIELD CONTROL STAND C5

 

0F9832EGS0R

1

SHIELD CONTROL STAND C5

 

0F9832HGS0R

1

SHIELD CONTROL STAND C5

 

0F9832JGS0R

1

SHIELD CONTROL STAND C5

B

0F9832FGS0R

1

SHIELD CONTROL STAND C5

C

0C2464

3

SCREW THF M6-1 X 16 N WA Z/JS

Image 67
Contents 25kW Models Standby Generator Sets Table of Contents  Warning   Electrical Hazards  ‹ Read this Manual Thoroughly ‹ Operation and Maintenance‹ HOW to Obtain Service Introduction‹ Data Label Identification RecordEngine OIL Recommendations Equipment DescriptionCoolant Recommendations Engine Protective Devices ‹ LP Fuel System Fuel System‹ Fuel Requirements ‹ Natural GAS Fuel SystemSpecifications ‹ Cold Weather KIT ‹ Reconfiguring the Fuel SystemGenerator AC Lead Connections Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator ‹ 3-PHASE AlternatorsPreparation Before START-UP InstallationInitial Inspection for Genset Startup ‹ Preparation for START-UP START-UP Checklist‹ Retransfer and Shutdown Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Engine START-UP and TransferCooling System Maintenance Performed by Service FacilitiesChecking Fluid Levels Maintenance Owner Operator can Perform ‹ Changing Engine OIL ‹ Changing the Engine AIR Cleaner ‹ Coolant Change‹ Spark Plugs Repair Parts Miscellaneous MaintenanceKW 150 KW Standby GAS Engine Driven Generator Sets Service ScheduleMaintenance Level 11-3 11-4 Problem Cause Correction Troubleshooting GuideStandby Generator Sets Standby Generator Sets Page PAN CB Conn BOX Page UL Circuit Breaker QJ-2P Page Assy STR 390 25AD1 CPL Page Components Included in 0G2283D Page Weldment Frame 2.4L C2 Page Battery Tray C1 CPL Page Gasket Bosch 32 Page Engine 2.4L Mitsubishi 4G64 Page Weldment Radiator Support 2.4L Page Flange Fuel Inlet Page Rear Wrap C2 CPL Page Exhaust Elbow 2 1/4 OD 2 1/2OD Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page C2 Units 04/07 a .Rev BackPg001

2.4L specifications

Generac Power Systems has established itself as a leading provider of energy solutions, and its 2.4L engine is a testimony to their commitment to innovation and reliability. This engine is designed for portable and standby generators, delivering exceptional performance and efficiency.

One of the standout features of the Generac 2.4L engine is its robust design, optimized for both heavy-duty use and demanding applications. The engineering focus ensures that the engine can withstand various environmental conditions while maintaining optimal operation. Additionally, its compact size makes it versatile for various generator models, making it a favored choice among manufacturers and users.

The 2.4L engine incorporates advanced technologies that enhance performance and fuel efficiency. One notable technology is the Electronic Fuel Injection (EFI) system. Unlike traditional carbureted engines, the EFI system provides precise fuel management, improving fuel efficiency and reducing emissions. This means users can expect longer run times on a single tank of fuel, a crucial advantage for those requiring power during outages or remote operation.

Furthermore, the Generac 2.4L engine is equipped with a state-of-the-art cooling system that maintains optimal operating temperatures even under heavy loads. This safeguard helps prevent overheating, thus extending the engine's longevity and reliability. The engine's low oil pressure shutdown feature adds another layer of protection by automatically shutting down the engine if oil pressure drops below a safe threshold.

Noise reduction is another priority for Generac, and the 2.4L engine reflects this commitment. With an integrated muffler and sound suppression features, the engine operates quietly without sacrificing power output. This is particularly beneficial for residential areas or environments where noise may be a concern.

In terms of maintenance, the Generac 2.4L engine requires minimal upkeep. Its design includes easily accessible components, allowing for straightforward maintenance routines. Regular oil changes and filter replacements ensure that the engine continues to perform at its best over time, providing users with peace of mind.

Overall, the Generac Power Systems 2.4L engine combines innovative features, advanced technologies, and reliable performance, making it an attractive choice for those in need of dependable power solutions. Whether for home backup or professional use, this engine exemplifies Generac's dedication to quality and user satisfaction.