Generac Power Systems owner manual Engine 2.4L Mitsubishi 4G64

Page 42

1

0G0408

1

ENGINE 2.4L MITSUBISHI 4G64

2

046526

3

WASHER LOCK M10

3

039414

4

SCREW HHC M8-1.25 X 35 G8.8

4

0G0149

1

SCREW SHC M14-1.5 X 35 G10.9

5

0E9868A

1

ALTERNATOR DC W/OUT PULLEY

(2) 6

0F3217

1

SPACER DC ALTERNATOR PULLEY

7

042574

1

ADAPTOR 1/8 NPTF TO 1/8 BSPT

8

0A8584

1

SWITCH OIL PRESSURE 10 PSI 2 POL (R-PANEL)

 

0F4612

1

SENDER OIL PRESSURE 1/8" NPT (H-PANEL)

9

057772

1

WASHER NYLON .565

10

057765

1

ADAPTER M14-1.50 X 3/8 NPT

11

043790

1

BARBED EL 90 3/8 NPT X 3/8

12

0C7649

1

CLAMP HOSE .38-.87

13

069860E

1

HOSE DRAIN ASSY 28"

14

063076

7

WASHER FLAT .531 ID X 1.062 OD

15

0G1394

7

SCREW HHC M12-1.25 X 20 G10.9

16

052830

2

SCREW HHC M10-1.25 X 45 G8.8

17

025507

5

WASHER SHAKEPROOF EXT 7/16 STL

18

062963

3

SCREW HHC M10-1.25 X 30 G8.8

19

049821

3

SCREW SHC M8-1.25 X 30 G12.9

20

022129

26

WASHER LOCK M8-5/16

21

0D6029

3

SCREW THF M6-1 X 16 N WA Z/JS

22

0A6751

1

SWITCH HI-TEMP 245D X 3/8 NPT (R-PANEL)

 

0E0502

1

TEMPERATURE SENDER DELPHI (H-PANEL)

23

022145

7

WASHER FLAT 5/16-M8 ZINC

25

045771

3

NUT HEX M8-1.25 G8 CLEAR ZINC

26

022131

1

WASHER FLAT 3/8-M10 ZINC

27

049813

3

NUT HEX M6 X 1.0 G8 YEL CHR

28

046525

2

NUT HEX M10-1.25 G8 YEL CHR

29

058306

15

SCREW SHC M8-1.25 X 25 G12.9

30

022097

7

WASHER LOCK M6-1/4

31

022473

10

WASHER FLAT 1/4-M6 ZINC

32

043116

4

SCREW HHC M6-1.0 X 12 G8.8

33

026073A

2

PLUG STD PIPE 1/4 STEEL SQ HD

34

052243

1

SCREW HHC M10-1.5 X 60 G8.8

35

0A8258

1

SCREW HHC M8-1.25 X 25 G10.9

(1) 36

0G0664

1(REF)

OIL FILTER G2 ENGINE

37

0G1502

1

COIL PACK

38

047290

1

HOSE 3/8 ID SINGLE BRAID (15” LG)

39

049340

1

BARBED EL 90 1/4 NPT X 3/8

(3) 40

045757

1

SCREW HHC M6-1.0 X 25 G8.8

(1) 44

0G0951

1(REF)

GASKET EXHAUST MANIFOLD

45

0G3910

1

EXHAUST MANIFOLD G2 (MACHINE) (35KW & 45KW)

 

0G0608

1

MANIFOLD EXHAUST (MACHINED) (25KW ONLY)

46

0F9965E

1

FLEX PLATE 2 POLE 2.4L G2

47

0D2244M

2

ASSY MAGPICKUP(3/8-24 MALE)

48

0F9420

1

ADAPTER ENGINE 2.4L MACHINE

49

0E9747

1

STARTER, 12 VOLT

50

0G1472A

1

CAM SENSOR PIN ASSY

51

0G1476

1(REF)

COVER CAM GEAR G2 REWORKED

52

0G0707

1

MANIFOLD INTAKE

(1) 53

0G0950

1(REF)

GASKET INTAKE MANIFOLD

54

0F9583

1

SPACER 2.4L G2 FLEX PLATE

55

0G0792

1

SHIELD HEAT G2

56

0G0792A

1

SHIELD HEAT SML

57

0G1501

1

BRACKET COIL PACK

59

0F9501

1

ADAPTER 2.4L CRANKSHAFT MACH

(1) 60

0G0952

1(REF)

POLY V-BELT G2 (3600 RPM)

 

0D3488S

1

BELT SERPENTINE 37.0" (1800 RPM)

61

0G0788

1

PULLEY DC ALTERNATOR (3600 RPM)

 

0G2750

1

PULLEY 69 OD DC ALTERNATOR (1800 RPM)

62

049721

3

SCREW HHC M6-1.0 X 35 G8.8 BLK

63

026925

1

PLUG STD PIPE 3/8 STEEL SQ HD

(3) 64

0F2776

1

BRACKET, SIGNAL CONDITIONER

65

052203

2

SCREW HHC M8-1.25 X 70 G8.8

(3) 66

0F2776D

1

BRACKET SIGNAL CONDITONER

 

 

 

(1) SUPPLIED WITH ENGINE.

 

 

 

(2) NOT USED ON 1800 RPM UNITS.

 

 

 

(3) USED WITH H-PANEL ONLY

Image 42
Contents 25kW Models Standby Generator Sets Table of Contents  Warning   Electrical Hazards  Introduction ‹ Operation and Maintenance‹ HOW to Obtain Service ‹ Read this Manual ThoroughlyIdentification Record ‹ Data LabelEquipment Description Engine OIL RecommendationsCoolant Recommendations Engine Protective Devices ‹ Natural GAS Fuel System Fuel System‹ Fuel Requirements ‹ LP Fuel SystemSpecifications ‹ Reconfiguring the Fuel System ‹ Cold Weather KIT‹ 3-PHASE Alternators Alternator Power Winding Connections‹ FOUR-LEAD, SINGLE-PHASE Stator Generator AC Lead ConnectionsInstallation Preparation Before START-UPInitial Inspection for Genset Startup START-UP Checklist ‹ Preparation for START-UP‹ Engine START-UP and Transfer Operating Unit with Manual Transfer SwitchGenerator Control Operation ‹ Retransfer and ShutdownMaintenance Performed by Service Facilities Cooling SystemChecking Fluid Levels Maintenance Owner Operator can Perform ‹ Changing the Engine AIR Cleaner ‹ Coolant Change ‹ Changing Engine OIL‹ Spark Plugs Miscellaneous Maintenance Repair PartsService Schedule KW 150 KW Standby GAS Engine Driven Generator SetsMaintenance Level 11-3 11-4 Troubleshooting Guide Problem Cause CorrectionStandby Generator Sets Standby Generator Sets Page PAN CB Conn BOX Page UL Circuit Breaker QJ-2P Page Assy STR 390 25AD1 CPL Page Components Included in 0G2283D Page Weldment Frame 2.4L C2 Page Battery Tray C1 CPL Page Gasket Bosch 32 Page Engine 2.4L Mitsubishi 4G64 Page Weldment Radiator Support 2.4L Page Flange Fuel Inlet Page Rear Wrap C2 CPL Page Exhaust Elbow 2 1/4 OD 2 1/2OD Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page C2 Units 04/07 a .Rev BackPg001

2.4L specifications

Generac Power Systems has established itself as a leading provider of energy solutions, and its 2.4L engine is a testimony to their commitment to innovation and reliability. This engine is designed for portable and standby generators, delivering exceptional performance and efficiency.

One of the standout features of the Generac 2.4L engine is its robust design, optimized for both heavy-duty use and demanding applications. The engineering focus ensures that the engine can withstand various environmental conditions while maintaining optimal operation. Additionally, its compact size makes it versatile for various generator models, making it a favored choice among manufacturers and users.

The 2.4L engine incorporates advanced technologies that enhance performance and fuel efficiency. One notable technology is the Electronic Fuel Injection (EFI) system. Unlike traditional carbureted engines, the EFI system provides precise fuel management, improving fuel efficiency and reducing emissions. This means users can expect longer run times on a single tank of fuel, a crucial advantage for those requiring power during outages or remote operation.

Furthermore, the Generac 2.4L engine is equipped with a state-of-the-art cooling system that maintains optimal operating temperatures even under heavy loads. This safeguard helps prevent overheating, thus extending the engine's longevity and reliability. The engine's low oil pressure shutdown feature adds another layer of protection by automatically shutting down the engine if oil pressure drops below a safe threshold.

Noise reduction is another priority for Generac, and the 2.4L engine reflects this commitment. With an integrated muffler and sound suppression features, the engine operates quietly without sacrificing power output. This is particularly beneficial for residential areas or environments where noise may be a concern.

In terms of maintenance, the Generac 2.4L engine requires minimal upkeep. Its design includes easily accessible components, allowing for straightforward maintenance routines. Regular oil changes and filter replacements ensure that the engine continues to perform at its best over time, providing users with peace of mind.

Overall, the Generac Power Systems 2.4L engine combines innovative features, advanced technologies, and reliable performance, making it an attractive choice for those in need of dependable power solutions. Whether for home backup or professional use, this engine exemplifies Generac's dedication to quality and user satisfaction.