Emerson 3051S manual EA Wizard View

Page 31

Reference Manual

00809-0200-4801, Rev BA April 2007

Rosemount 3051S

Figure 3-9. EA Wizard View

EA Wizard

4.Upon completing a mass flow configuration using the EA Wizard, the file can be saved to disk. The file must be saved for review or to edit the mass flow configuration file in the future. FOUNDATION Fieldbus mass flow configuration files cannot be uploaded from the Mass Flow Transducer Block. If the file is not saved, it cannot be retrieved.

5.Select the “Send” button to download the mass flow configuration file to the Mass Flow Transducer Block. Sending the mass flow configuration file will overwrite the existing file in the Mass Flow Transducer Block. The transmitter must be out of service to send a mass flow configuration file.

6.A message box will appear confirming the action to send the mass flow configuration file to the Mass Flow Transducer Block. Select “OK” to send the mass flow configuration file.

7.Completing the download of the file to the Mass Flow Transducer Block, a screen that says “Installation Completed Successfully” will appear. Select OK.

8.The installation is now complete and will appear in the Device Status portion of the screen.

9.Bring the transmitter back into service using the host system, for example DeltaV.

3-31

Image 31
Contents Reference Manual Overview Safety MessagesNetwork Parameter Value Device Capabilities Link Active SchedulerMAN General Block InformationModes AutoResource Block FeaturesFeaturessel Block Instantiation SimulationRead/Write Write accessMaxnotify Hwsel bit Swsel bitPlantWeb Alarms Maintmask MaintalarmsMaintenabled AdviseenabledAnalog Input AI Function Block Configure the AI blockLtype ChannelChannel Number Channel Description Pressure Channel Temperature Channel Flow Channel Parameter Configured Values Configuration ExamplesSituation #3 Diagram XDSCALE100 OUT= Low Cutoff FilteringHipri Hihipri Lopri Lolopri Process AlarmsAlarm Priority Status OptionsOutd Advanced FeaturesAlarmtype Multiple Analog Input MAI Function BlockNumber Name and Description Block Error ConditionsLCD Transducer Block Custom Meter ConfigurationCUSTOMTAG#1 DisplayparamselBLKTYPE#1 PARAMINDEX#1CUSTOMUNITS#1 Display bar graphCustom ADB Parameters Plugged Impulse Line Detection PIL Advanced Diagnostics Transducer Block ADBPlineon Configuration Plugged Impulse Line DetectionPlugged Impulse Line Advanced Settings Rosemount 3051S Statistical Process Monitoring SPM SPM Configuration Mass Flow Engineering Assistant Software Installation and SetupDevice View Open EA Wizard EA Wizard View 10. Download Mass Flow Configuration File
Related manuals
Manual 34 pages 49.8 Kb Manual 36 pages 50 Kb

3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.