Emerson 3051S manual Device View

Page 29

Reference Manual

00809-0200-4801, Rev BA April 2007

Rosemount 3051S

Establish Communications with the 3051S FOUNDATION Fieldbus Transmitter using 3095 EA for FOUNDATION Fieldbus

1.Connect the 9-pin communications cable into the PCMCIA card port located in the computer.

2.Connect communication wiring to the cable connectors labeled “D+” and “D-”.

3.Open the transmitter cover on the side marked “Field Terminals”. Connect the communication wires to the 3051S transmitter terminals labeled “Fieldbus Wiring”.

4.Verify device is properly powered to establish communications.

5.Open the 3051S Engineering Assistant for FOUNDATION Fieldbus program. Select the 3051S Engineering Assistant for FOUNDATION Fieldbus from the program menu or use the 3051S EA for FF shortcut icon.

6.Select Scan to scan the FOUNDATION Fieldbus segment. Scanning will locate and present live 3051S or 3095 FOUNDATION Fieldbus transmitters on the segment that has a licensed mass flow block. The transmitter device tag name will appear on the screen in the Device view. The Device Status view will publish the status of the transmitter.

7.FOUNDATION Fieldbus communication status is represented in the lower right corner of the screen. If status is ONLINE, communication has been established. If status is OFFLINE, communication has not been established and/or communication has been disconnected.

Figure 3-7. Device View

Scan fieldbus Segment

3051S Device Tag Name(s) on Segment

Selected Device Status

Communication Status ONLINE or OFFLINE

3-29

Image 29
Contents Reference Manual Overview Safety MessagesNetwork Parameter Value Device Capabilities Link Active SchedulerModes General Block InformationAuto MANFeaturessel FeaturesBlock Instantiation Simulation Resource BlockMaxnotify Write accessHwsel bit Swsel bit Read/WritePlantWeb Alarms Maintenabled MaintalarmsAdviseenabled MaintmaskAnalog Input AI Function Block Configure the AI blockChannel Number Channel Description ChannelLtype Pressure Channel Temperature Channel Flow Channel Parameter Configured Values Configuration ExamplesSituation #3 Diagram XDSCALE100 OUT= Low Cutoff FilteringAlarm Priority Process AlarmsStatus Options Hipri Hihipri Lopri LolopriAlarmtype Advanced FeaturesMultiple Analog Input MAI Function Block OutdNumber Name and Description Block Error ConditionsLCD Transducer Block Custom Meter ConfigurationBLKTYPE#1 DisplayparamselPARAMINDEX#1 CUSTOMTAG#1Custom Display bar graphCUSTOMUNITS#1 ADB Parameters Plugged Impulse Line Detection PIL Advanced Diagnostics Transducer Block ADBPlineon Configuration Plugged Impulse Line DetectionPlugged Impulse Line Advanced Settings Rosemount 3051S Statistical Process Monitoring SPM SPM Configuration Mass Flow Engineering Assistant Software Installation and SetupDevice View Open EA Wizard EA Wizard View 10. Download Mass Flow Configuration File
Related manuals
Manual 34 pages 49.8 Kb Manual 36 pages 50 Kb

3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.