Emerson 3051S manual Engineering Assistant Software, Installation and Setup

Page 28

Rosemount 3051S

Reference Manual

00809-0200-4801, Rev BA April 2007

ENGINEERING ASSISTANT SOFTWARE

Installation and Setup

If you already own a National Instruments Fieldbus interface device, you can go to rosemount.com to download the 3051S revision 23 Device Description. If you don’t already own a National Instruments Fieldbus interface device, contact your local sales person for ordering options.

NOTE

Could affect block execution times.

Installing the 3051S Engineering Assistant for FOUNDATION Fieldbus

Operation of the software requires installation of both the 3051S Engineering Assistant (EA) for FOUNDATION Fieldbus program and FOUNDATION Fieldbus communication card drivers. The 3051S Engineering Assistant for FOUNDATION Fieldbus and 3051S Engineering Assistant for HART can be loaded onto the same computer. However, the programs cannot be opened simultaneously. Upgrades for the 3051S Engineering Assistant are available on www.rosemount.com.

1.Follow the instructions below to complete required software installation.

a.Place 3051S EA Software CD-ROM disk 2 into the disk drive.

b.Browse and select the EA-Ff folder using Windows NT, 2000, or XP.

c.Open the ReadMe.txt file and follow the instructions provided.

2.Install the FOUNDATION Fieldbus PCMCIA communications card into the machine by following instructions provided with the card. Installation of the communications card is not required for offline operation of the 3051S EA for FOUNDATION Fieldbus software program.

3-28

Image 28
Contents Overview Safety Messages Reference ManualDevice Capabilities Link Active Scheduler Network Parameter ValueGeneral Block Information ModesAuto MANFeatures FeaturesselBlock Instantiation Simulation Resource BlockWrite access MaxnotifyHwsel bit Swsel bit Read/WritePlantWeb Alarms Maintalarms MaintenabledAdviseenabled MaintmaskConfigure the AI block Analog Input AI Function BlockLtype ChannelChannel Number Channel Description Pressure Channel Temperature Channel Flow Channel Configuration Examples Parameter Configured ValuesSituation #3 Diagram XDSCALE100 OUT= Filtering Low CutoffProcess Alarms Alarm PriorityStatus Options Hipri Hihipri Lopri LolopriAdvanced Features AlarmtypeMultiple Analog Input MAI Function Block OutdBlock Error Conditions Number Name and DescriptionCustom Meter Configuration LCD Transducer BlockDisplayparamsel BLKTYPE#1PARAMINDEX#1 CUSTOMTAG#1CUSTOMUNITS#1 Display bar graphCustom Advanced Diagnostics Transducer Block ADB ADB Parameters Plugged Impulse Line Detection PILConfiguration Plugged Impulse Line Detection PlineonPlugged Impulse Line Advanced Settings Rosemount 3051S Statistical Process Monitoring SPM SPM Configuration Mass Flow Installation and Setup Engineering Assistant SoftwareDevice View Open EA Wizard EA Wizard View 10. Download Mass Flow Configuration File
Related manuals
Manual 34 pages 49.8 Kb Manual 36 pages 50 Kb

3051S specifications

The Emerson 3051S is a state-of-the-art pressure transmitter that excels in various industrial applications. Its design is rooted in cutting-edge technology, ensuring accurate and reliable pressure measurements. With a focus on performance and durability, the 3051S stands as a trusted choice for engineers and process professionals worldwide.

One of the standout features of the Emerson 3051S is its advanced sensor technology. The device utilizes a high-performance sensor that offers exceptional accuracy, with a measured performance of up to ±0.075% of the span. This precision is essential for processes where minute changes in pressure can significantly impact operations. Coupled with the sensor's stability and repeatability, the 3051S provides consistent readings even in fluctuating conditions.

The device also incorporates Emerson's proprietary Smart Pressure technology, which enables predictive diagnostics. This feature allows users to anticipate potential issues before they escalate, reducing downtime and maintenance costs. The 3051S is equipped with advanced communication capabilities, supporting protocols such as HART, FOUNDATION Fieldbus, and Profibus PA. This versatility ensures seamless integration into existing plant automation systems, facilitating real-time data monitoring and management.

In terms of construction, the Emerson 3051S is built to withstand harsh industrial environments. It features a robust stainless-steel housing that protects the internal components from corrosive substances, high temperatures, and extreme pressures. The device is also available with various membrane materials, making it suitable for a wide range of media, including corrosive and viscous fluids.

Moreover, the 3051S is designed with user-friendliness in mind. It includes an intuitive interface and is fully configurable, allowing for easy calibration and setup. The ability to use Emerson's AMS Device Manager software further enhances the user experience, enabling detailed analysis, configuration, and diagnostics from a centralized platform.

Overall, the Emerson 3051S combines superior technology with practical design, making it an ideal solution for industries such as oil and gas, chemical processing, and water treatment. Its precise measurements, advanced diagnostics, and durable construction position it as a benchmark in the field of pressure transmitters, delivering reliability and efficiency for critical applications.