Emerson CF220AGW00, CF220GBZ00, CF220GLZ00 owner manual PIN Hanger Ball Downrod Setscrew Hairpin

Page 8

BP7360 JULIANNE 9/19/07 11:15 AM Page 8

11. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 7). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 18.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 8) could result in the fan falling.

PIN

HANGER

BALL

DOWNROD

SETSCREW

 

DOWNROD

HAIRPIN

CLEVIS

CLIP

 

PIN

MOTOR

 

COUPLING

 

Figure 7

NOTE: If you have an eight-foot ceiling, you will have to use the 6” downrod (supplied) in order to maintain the necessary blade-to-floor clearance of seven feet.

12. Unscrew the two upper setscrews (Figure 8) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 8). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull up on the downrod to make sure the clevis pin is properly installed.

SETSCREW (2)

Figure 8

13. Tighten the two upper setscrews (Figure 8) securely while pulling up on the downrod.

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

14. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover over the downrod until it rests on the motor housing (Figure 9).

NOTE: If you installed the 6” downrod, the three downrod scrolls and scroll retaining ring will not be installed. Disregard steps 15 through 17; proceed to step 18.

8

U.L. Model No.: CF220

 

Image 8
Contents Aged Walnut with Teak/Mahogany Blades Model NumbersDark Cherry Date Code Safety InstructionsAdditional Safety Instructions for Installation Materials Unpacking InstructionsEmerson General Electrical Requirements Ceiling Fan ProceduresHow to Assemble Your Ceiling Fan Flat Washer FAN Blade Blade Flange Switch CUP Assembly PIN Hanger Ball Downrod Setscrew Hairpin Downrod Setscrew How to Hang Your Ceiling Fan TABHow to Wire Your Ceiling Fan StudSW101 FAN/LIGHT Wall Control Supplied Black To HOT Installation of Wall Control Setting Operating Frequency of Wall Control and ReceiverRequired WAY WIRlNG Diagram NEW Construction Do not connect any neutral whiteOn position.REVERSING Switch Operating Your Ceiling FanFor your Ceiling Fan MaintenanceAccessoriesImportant Care Instructions Trouble Shooting Trouble Probable Cause Suggested RemedyRepair Parts HOW to Order Repair PartsRepair Parts Listing Key Model No DescriptionLimited Warranty Air Comfort Products