Information Bulletin 120697 Continued from previous Page
Electrical connection:
Identify the plus (+) lead running to the solenoid for the tilt function. This solenoid is located across the valve from the fitting you installed. Remove approximately 2 " of the outer plastic covering from the wires coming from the solenoid. Splice one of the 18 gauge wires you provided into one of the wires. Connect the other end of that wire to a lug on the solenoid. It makes a difference which wire runs to which connector. Insulate any exposed wires with electrical tape.
Note orientation of notch in plate
To Valve
Very Important ! DO NOT use
Solenoids as handles
Port | Port |
Wire connector Lugs
Door
Tilt
Dipper
Lift
Swing
Steps to take to install the tilt cylinder lock valve
Hydraulic Connections
1.Remove the tilt section hose from the
2.Assemble the parts as shown above.
3.Attach the hose to the fitting on Lock valve, Test and run.
TECHNICAL INFORMATION BULLETIN
No. 120697
This document does not authorize the repair or replacement of parts under warranty
MACHETE
© 2005 Alamo Group Inc. |