4.1.11Check hydraulic oil level:

Service Interval: 40 hr.

a)Stop engine and wait for all moving parts to stop.

b)Clean area around hydraulic reservoir cap and remove cap.

c)Oil level should be to the top of the baffle inside the tank. If not add oil. Use only Mobil 1 15W-50 synthetic motor oil. Replace hydraulic reservoir cap and tighten until snug. Do not overtighten.

NOTE: The baffle is labeled “HOT” and “COLD”. The oil level varies with the temperature of the oil. The “HOT” level shows the level of oil when it is at 225°F (107°C). The “COLD” level shows the level of the oil when it is at 75°F (24°C). Fill to the appropriate level depending upon the temperature of the oil. For example: If the oil is about 150° F (65°C), fill to halfway between the “HOT” and “COLD” levels. If the oil is at room temperature (about 75° F (24°C)), fill only to the “COLD” level.

4.1.12Check tire pressures:

Service Interval: 40 hrs.

a)Stop engine, wait for all moving parts to stop, and remove key.

b)Check tire pressure in all four tires.

c)Inflate caster tires to 16 psi (1100 kPa).

d)Inflate drive tires to 13 psi (90 kPa).

NOTE: Do not add any type of tire liner or foam fill material to the tires. Excessive loads created by foam filled tires may cause failures to the hydro drive system, frame and other components. Foam filling tires will void the warranty.

4.1.13Check condition of belts:

Service Interval: 40 hrs.

a)Stop engine, wait for all moving parts to stop, and remove key.

b)Check under engine deck to check pump drive belt.

c)Remove left and right belt shields on deck and lift up floor pan to inspect deck drive belt.

d)See Sections 4.2.3 and 4.2.4, for belt adjustment.

4.1.14Lubricate grease fittings:

Service Interval: Refer to chart.

a)Stop engine, wait for all moving parts to stop, and remove key.

b)Lubricate fittings with one to two pumps of NGLI grade #2 multi-purpose gun grease.

Refer to the following chart for fitting locations and lubrication schedule.

23

Image 28
Contents For Serial Nos 600,000 & Higher Potential Hazard Exmark Parts PLUS→ Program Operators Manual Table of Contents Safety Your Safety is InvolvedSafety Alert Symbol TrainingCarbon monoxide can kill you Potential Hazard Operation Safe Zone for Mowing There is no rollover protection when the roll bar is down Maintenance and Storage Safety Signs Page Specifications Model NumberEngine Fuel SystemElectrical System Operator ControlsDimensions Hydrostatic Ground Drive SystemTires and Wheels Cutting DeckTorque Requirements Operation InstructionsControls Motion Control Positions Push the lever forward and down to disengage the brake PRE-START MowingTransporting Potential HazardMaintenance & Adjustments Periodic Maintenance Service Interval DailyService Interval Daily or more often in dry conditions Service Interval MonthlyPotential Hazard Blade Bolt Installation Check rollover protections systems roll bar pins Service Interval 40 hrs Service Interval 40 hrService Interval Refer to chart Service Interval Once Yearly Lubrication ChartCaster Wheel Assembly Service Interval 160 hrs Service Interval 80 hrsService Interval As Required Service Interval After First 250 hrs Then yearly thereafterAdjustments Cutting Height PositionANTI-SCALP Roller Adjustment Swivel Adjustment Spring Compression Adjustment Type a Park Brake Adjustment Type B Park Brake Adjustment Throttle TensionNo adjustment necessary RH Motion Control Adjustment LH Motion Control AdjustmentTrouble Shooting Waste DisposalEngine Troubleshooting Table ProblemBriggs & Stratton Electrical Diagram Hydraulic Diagram Year Limited Warranty Evaporative Emission Control Warranty Statement Page Page Service Record Page See EXMARK’S Complete Line of Accessories