Carrier 33ZCVAVTRM manuals
Household Appliance > Air Conditioner
When we buy new device such as Carrier 33ZCVAVTRM we often through away most of the documentation but the warranty.
Very often issues with Carrier 33ZCVAVTRM begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Carrier 33ZCVAVTRM is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
Carrier 33ZCVAVTRM Specifications
52 pages 900.39 Kb
Installation, Start-Up and Configuration InstructionsPart Numbers 33ZCFANTRM, 33ZCVAVTRM, 33ZCSECTRMCONTENTS SAFETY CONSIDERATIONS SAFETY NOTE 2 GENERALINSTALLATION General Zone Contr oller Hard w are Field-Suppl ied Hard ware 4 Mount Zone Controller 5 ZONE ControllerZONE ControllerCW COM COW J8 SEC DMP 1 3 Fig. 3 VAV Fan Terminal Zone Controller Fig. 4 Single Duct Air Terminal Zone Controller 6 ZONE ControllerUL Fig. 6 Service Clearance for Zone Controller Mounting Fig. 5 Secondary Terminal Zone ControllerZONE CONTROLLER ALLOW 12 CLEARANCE FOR SERVICE ACCESS TO CONTROL BOX 3 REF. 7 Connect the Power Transformer An individual,Connect Airflow Pickups The zone controller de-SAT SPT Wht RedBlk Ora BluYel 8 Fig. 8A Zone Controller Wiring Single Duct Air Terminal, Cooling Only9 HF23BJ04250/60Hz 24VAC/DC 80...110s 35 in-lb(4Nm) SAT SPT Low HiWhtRedBlk com Ora BluYel Fig. 8B Zone Controller Wiring Single Duct Air Terminal, Two-Position Hot Water Heat LEGEND *Normally open or normally closed valve may be used. 10 HF23BJ0422W 3VA Factory Wir ing50/60Hz 24VAC/DC 80...110s 35 in-lb(4Nm) SAT SPT Low HiWhtRedBlk com Ora BluYelcomunications CCN Not used comunications CCN Fig. 8C Zone Controller Wiring Single Duct Air Terminal, Modulating Hot Water Heat LEGEND *Required for some spring return modulating valves. 11 HF23BJ042Low HiWhtRedBlk com OraBluYel Fig. 8D Zone Controller Wiring Single Duct Air Terminal, Staged Electric Heat (2 Stages) LEGENDVoltage Line 2W 3VA 50/60Hz 24VAC/DC 12 HF23BJ04280...110s 35 in-lb(4Nm) Fig. 8E Zone Controller Wiring Single Duct Air Terminals, Staged Electric Heat (3-Stage) Low HiWhtRedBlk com Ora BluYelTRAN Factory Wir ing NOTE: The VAV fan terminal zone controller is used on single duct air terminals with 3 stages of electric heat. 13 MHF23BJ042 Low HiWhtRedBlk com OraBluYel Fig. 8F Zone Controller Wiring Fan Powered Terminals, Cooling Only 14 MHF23BJ042 Low HiWhtRedBlk com OraBluYel Fig. 8G Zone Controller Wiring Fan Powered Terminals, Two-Position Hot Water HeatFan Motor Voltage Fan Contactor 50/60Hz Line Voltage Line 15 M2W 3VA PAT Primary Air Temperature Sensor LEGEND HF23BJ04224VAC/DC 80...110s 35 in-lb(4Nm) SAT SPT Low HiWhtRedBlk com OraBluYel PAT*Not Used comunications CCN comunications CCN Fig. 8H Zone Controller Wiring Fan Powered Terminals, Modulating Hot Water Heat*Required only on Linkage master if on a non-compatible air source. 16 M
Also you can find more Carrier manuals or manuals for other Household Appliance.