Carrier 48P2 manuals
Household Appliance > Electric Heater
When we buy new device such as Carrier 48P2 we often through away most of the documentation but the warranty.
Very often issues with Carrier 48P2 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Electric Heater Carrier 48P2 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Electric Heater on our side using links below.
Carrier 48P2 Installation Instructions
76 pages 5.78 Mb
Installation InstructionsCONTENTS GENERAL SAFETY CONSIDERATIONS FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY 2 INSTALLATION Step 1 Perform Jobsite Survey Step 2 Place Unit Step 3 Roof Mount Unit Step 4 Slab Mount Unit Step 5 Install Curb Gasketing Step 6 Install Field-Fabricated Ductwork Step 7 Rig Unit 3 Table 1A Physical Data 48P2,P3,P4,P5030-0504 Table 1A Physical Data 48P2,P3,P4,P5030-050 (cont)5 Table 1B Physical Data 48P2,P3,P4,P5055-0706 Table 1C Physical Data 48P2,P3,P4,P5075-1007 Table 1C Physical Data 48P2,P3,P4,P5075-100 (cont)Table 2 Optional Return Fan Physical Data (48P075-100 Only) Table 4 Optional Humidi-MiZer Coil Data Table 3 Optional High-Capacity Power Exhaust Physical Data (48P075-100 Only) 8 Table 5 Operating Weights of Options and Accessories (lb)Table 6 Supply Fan Drive Data 9 Table 7 Power Exhaust Fan Drive DataTable 8 Optional High-Capacity Power Exhaust Fan Drive Data Table 9 Optional Return Fan Drive Data 16 Step 8 Connect Condensate Drain ALL PANELS MUST BE IN PLACE WHEN RIGGING.NOTE: Rig with four cables and spread with two 95 inch (2413 MM) spreader bars. 17 CAUTION - NOTICE TO RIGGERS:NOTE: 1. Weights do not include economizer or power exhaust. Fig. 9 Rigging Label Units without Optional Return Fan or High-Capacity Power Exhaust ALL PANELS MUST BE IN PLACE WHEN RIGGING.NOTE: Rig with four cables and spread with two 95 inch (2413 MM) spreader bars. a48-8456 18 CAUTION - NOTICE TO RIGGERS:Fig. 10 Rigging Label Units with Optional Return Fan or High-Capacity Power Exhaust 19 Fig. 11 Weight Distribution and Center of Gravity32 Step 9 Install Outdoor Hoods (Units without Optional High-Capacity Power Exhaust)33 Step 10 Install Economizer Hoods (Units with Optional High-Capacity Power Exhaust) 35 Step 11 Route Field WiringStep 12 Make Field Electrical Connections38 Table 10 Electrical Data, 48P2,P3,P4,P5030 Units39 Table 10 Electrical Data, 48P2,P3,P4,P5030 Units (cont)40 Table 11 Electrical Data, 48P2,P3,P4,P5035 Units41 Table 11 Electrical Data, 48P2,P3,P4,P5035 Units (cont)42 Table 12 Electrical Data, 48P2,P3,P4,P5040 Units43 Table 12 Electrical Data, 48P2,P3,P4,P5040 Units (cont)44 Table 13 Electrical Data, 48P2,P3,P4,P5050 Units45 Table 13 Electrical Data, 48P2,P3,P4,P5050 Units (cont)46 Table 14 Electrical Data, 48P2,P3,P4,P5055 Units47 Table 15 Electrical Data, 48P2,P3,P4,P5060 Units48 Table 16 Electrical Data, 48P2,P3,P4,P5070 Units49 Table 17 Electrical Data 48P2,P3,P4,P5075 Standard Units50 Table 18 Electrical Data 48P2,P3,P4,P5075 Units with Optional High-Capacity Power Exhaust51 Table 19 Electrical Data 48P2,P3,P4,P5075 Units with Optional Return Fan52 Table 20 Electrical Data 48P2,P3,P4,P5090 Standard Units53 Table 21 Electrical Data 48P2,P3,P4,P5090 Units with Optional High-Capacity Power Exhaust54 Table 22 Electrical Data 48P2,P3,P4,P5090 Units with Optional Return Fan55 Table 23 Electrical Data 48P2,P3,P4,P5100 Standard Units56 Table 24 Electrical Data 48P2,P3,P4,P5100 Units with Optional High-Capacity Power Exhaust57 Table 25 Electrical Data 48P2,P3,P4,P5100 Units with Optional Return Fan 58 Step 13 Connect Air Pressure Tubing 60 Step 14 Remove Supply-Fan Shipping Brackets Step 15 Remove Optional Return-Fan Ship- ping Brackets 61 Step 16 Connect Gas Piping Step 17 Configure Optional Staged Gas or Modulating Gas Control 62 Step 18 Install Flue/Inlet Hoods and Baffles Step 19 Install Supply-Air Thermistors (Staged and Modulating Gas Units Only) 66 Step 20 Install Optional Motormaster V Control 68 Step 21 Install Unit Accessories CONTROLS INSTALLATION Constant Volume (CV) Units Variable Air Volume (V AV) Units Option and Accessory Control Wiring 70 TB201
Also you can find more Carrier manuals or manuals for other Household Appliance.
Carrier 48P2 Specifications
8 pages 647.82 Kb
Users Information Manual48P2,P3,P4,P5030-100 Gas Heating/Electric Cooling Units with COMFORTLINK Controls3 Fig. 2 To Light Unit ON OFF 3 MAINESCAPE a48-8297 4 TO SHUT UNIT OFFMAINTAINING YOUR UNIT ROUTINE MAINTENANCE AND CARE FOR THE EQUIPMENT OWNER Air Filters Heat Exchanger 5 MAIN7 Fan and Belts Evaporator-Fan Motor, Condenser-Fan Motor and Combustion-Fan Motor Fan Shaft Bearings Evaporator and Condenser Coils Condensate Drain Compressors Condenser Fan Electrical Controls and Wiring Refrigerant Circuit Combustion Area and Vent System Unit Panels and Doors CAUTION 8 REGULAR DEALER MAINTENANCEBEFORE YOU CALL FOR SERVICE, CHECK FOR SEVERAL EASILY SOLVED PROBLEMS IN CASE OF TROUBLE