Fig. 61 — Flue Outlet Hood

Table 26 — Flue Hood, Inlet Hood, and Baffle Usage

HOOD OR

 

 

 

 

QUANTITY USED

 

 

BAFFLE TYPE

PARTS LIST

FIG. NO.

Sizes 030-050

Sizes 030-050

Sizes 055-070

Sizes 055-070

Sizes 075-100

Sizes 075-100

 

 

 

(Low Heat)

(High Heat)

(Low Heat)

(High Heat)

(Low Heat)

(High Heat)

 

Top (6-in.)

 

 

 

 

 

 

 

6-in. Inlet

Side (Left)

 

 

 

 

 

 

 

Side (Right)

65

1

1

1

1

Hood

Screen

 

 

 

 

 

 

 

 

Speed Clips

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

 

 

Top (14-in.)

 

 

 

 

 

 

 

 

Side (Left)

 

 

 

 

 

 

 

14-in. Inlet

Side (Right)

 

 

 

1

 

1

 

Screen

65,66

3

3

(Vertical

(Vertical

Hood

Cover

 

 

 

Supply Only)

 

Supply Only)

 

 

 

 

 

 

 

 

Speed Clips

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

 

 

Top (30-in.)

 

 

 

 

 

 

 

30-in. Inlet

Side (Left)

 

 

 

1

 

1

 

Side (Right)

 

 

 

 

 

67

(Horizontal

2

(Horizontal

2

Hood

Screen

 

 

 

Supply Only)

 

Supply Only)

 

 

Speed Clips

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

 

Flue Outlet

Pre-assembled

61

1

2

2

3

2

3

Hood

 

 

 

 

 

 

 

 

 

Flue Deflector

Hood

 

 

 

2

 

 

 

Deflector

 

 

 

 

 

 

62

1

2

(Horizontal

3

2

3

(V-Type)

Baffle

 

 

 

Supply Only)

 

 

 

 

Screws

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue Deflector

Hood

 

 

 

2

 

 

 

Deflector

 

 

 

 

 

 

63

(Vertical

(Curve-Type)

Baffle

 

 

 

Supply Only)

 

 

 

 

Screws

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-in. Baffle

Baffle

68

1

2

Screws

 

 

 

 

 

 

 

 

 

Baffle

 

 

 

1

 

1

 

30-in. Baffle

Screws

69

(Modulating

2

(Modulating

2

 

Horizontal

Horizontal

 

 

 

 

 

 

 

 

 

 

 

 

Supply Only)

 

Supply Only)

 

 

Fig. 61 — Flue Outlet Hood

 

 

FLUE DEFLECTOR

FLUE

 

BAFFLE

DEFLECTOR

 

PUSH

HOOD

 

BAFFLE

 

 

INLET BAFFLE

DOWN SO

 

(30-in.)

THESE 2

 

SCREW

 

 

 

 

HOLES

 

 

ALIGN

 

Fig. 60 — Baffle Locations, Sizes 055-100,

 

Modulating High Heat, Vertical and

a48-8587

Horizontal Supply Units

a48-8586

 

 