DeviceNet Network Scanner DVPDNET-SL
8 Setup of Slave Mode
DVPDNET-SL can serve as slave through modifying of the mode by software. As DVPDNET-SL serves as slave,
the default input / output data length is 8 bytes and max input / output data length is 255 bytes.
DVPDNET-SL can be set as slave mode in the following method.
1) Connect the devices according to below figure. PC accesses PLC MPU via RS232 or RS485.

DVP28SV

DVPDNET-SL

Device Net Builder

2) Open DeviceNet Builder software, and select “Setup” => “Communication Setting” => “System Channel”,
and the “Serial Port Setting” dialog box will appear as below.
3) Set up the communication parameters in the PC and DVP-SV, e.g. the communication port, address, baud
rate and communication format. Click on “OK” after configuration is finished.
Item Function Default
COM Port COM port on the PC to be used to communicate
with DVP-SV COM1
Address Communication address of DVP-SV 01
Baud rate Communication speed between the PC and
DVP-SV 9,600 (bps)
Data Bits 7
Parity Even Parity
Stop Bit
Communication protocol between the PC and
DVP-SV 1
Mode Communication mode between the PC and
DVP-SV ASCII
DVP-PLC Operation Manual
24