3Com Router 5000 and Router 6000 v2.41
Module Guide Chapter 1 Overview
1-5
Figure 1-2 Installing SIC

IV. Removing SIC

Follow these steps to remove a SIC:
Step 1: Place the rear panel of the Router towards you;
Step 2: Turn off the power switch of the Router and unplug the power cord;
Step 3: Unplug all the network interface cables connected to the rear panel of the
Router;
Step 4: Remove the captive screws on both sides of the SIC using the flat-blade
screwdriver;
Step 5: Pull the SIC outward until it is completely taken out of the Router chassis.
1.5.2 Installing/Removing MIM

I. Tools required

z Flat-blade screwdriver
z ESD-preventive wrist strap and ESD-preventive glove

II. Installing MIM

Follow these steps to install a MIM:
Step 1: Place the rear panel of the Router towards you;
Step 2: Turn off the power switch of the Router and unplug the power cord;
Step 3: Select a slot and insert the MIM along the guides in the slot until it contacts the
rear panel of the Router;
Step 4: Fix the MIM into the Router with captive screws;
Step 5: Power on the Router, and check the LEDs of the corresponding slot on the
front panel: ON means that the MIM is operating normally and OFF means that the
POST of the MIM has failed. In the latter case, please contact your agent.