26CHAPTER 2: INSTALLING THE SWITCH

Choosing a Suitable The Switch is suited for use in an office environment where it can be

Sitemounted in a standard 19-inch equipment rack, or free standing. Alternatively, the Switch can be rack-mounted in a wiring closet or equipment room. A rack-mounting kit, containing two mounting brackets and four screws, is supplied with the Switch.

When deciding where to position the Switch, ensure that:

You are able to meet the configuration rules detailed in “Configuration Rules for Fast Ethernet” on page 21.

The Switch is accessible and cables can be connected easily.

The switch is situated away from sources of conductive (electrical) dust, for example, laser printers

The AC supply used by the Switch is separate to that used by units that generate high levels of AC noise, for example air conditioning units and laser printers

Cabling is away from:

Sources of electrical noise such as radios, transmitters and broadband amplifiers

Power lines and fluorescent lighting fixtures

Water or moisture cannot enter the case of the Switch.

Air-flow is not restricted around the Switch or through the vents in the side of the Switch. We recommend that you provide a minimum of 25mm (1in.) clearance.

No more than four Switch units are placed on top of one another, if the units are free standing.

If used in an office environment, the switch is positioned so that any noise from the fan is not disruptive.