WAN Por ts
(8 & 9)
These ports are used to provide connection to a WAN over a private
leased line. The port terminates with a SCSI connector. This port
supports any of the CCITT data transmission standards; X.21/V.11
V.24/V.28 (RS232), and V.35/V.36 at data transfer rates up to 2 Mbps.
Provided that connection cables that follow these standards are used,
the unit automatically detects the type of interface that the port is
required to support, and configures it accordingly.
Refer to
AppendixA
for information about the WAN interface cables
required. Suitable cables are available from your 3Com reseller as spare
parts, refer to
AppendixA
for the required item part number.
The PRI Bridge/Router Module supports up to eight ISDN channels.
However, if you use a WAN port, one less ISDN channel can be supported.
If both WAN ports are used, a maximum of six ISDN channels can be