LOCATING AN ACTIVE DUCT PROBE (ADP)

LOCATING AN ACTIVE DUCT PROBE (ADP)

Press Determining ADP Depth to turn the Receiver on.

Press Manual background to select the 33 kHz frequency.

Press Manual background to select the Peak mode Manual background. If you find that the received signal is too weak in this mode, try the Special Peak mode. To select

Special Peak mode: from Peak mode, press and hold Manual background , then press Manual background to toggle between Peak and Special Peak modes. While in Special Peak mode, the Peak flag will flash.

With the Receiver handle perpendicular to the conduit path, locate the ADP position by moving along the path until a peak is found. Press Manual background when the bar graph remains either fully open or fully closed. Refer to the ADP operating instructions for further information.

Determining ADP Depth

Place the Receiver Antenna on the ground directly above the located ADP position maintaining the handle orientation perpendicular to the path.

Press Manual background twice to display ADP depth Manual background .

To return to trace mode, press Manual background or Manual background .

Note: During a depth-current measurement, the display will exhibit

'– – – ' when the received signal is too low, too high, or erratic.