22
Maintenance (Continued)
WARNING – Turn off electrical and air supplies and disconnect power cord from electrical
supply before beginning maintenance. If power cord is not disconnected, severe injury to
personnel could result.
Knife Replacement, Taping Head
See Section II, "Maintenance – Knife
Replacement", page 9.
Circuit Breaker
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical enclosure on the side of the
machine frame just below the machine bed, the
circuit breaker has been pre-set at 1.9 amps and
requires no further maintenance.
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Remove electrical enclosure cover.
3. Press the red "Reset" button and then the
green "Start" button.
4. Replace cover.
5. Plug in machine.
6. Press machine "On" button to resume case
sealing.
WARNING – The following
procedure must be performed by
trained service personnel because of the
high voltage electrical hazard within the
control box.