15
Installation and Set-Up (Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles box
sizes up to 620 mm [24.5 inch] maximum height.
If larger capacity is needed, the machine can be
adjusted to accommodate boxes up to 725 mm
[28.5 inch] high. Refer to "Special Set-Up
Procedure – Box and Machine Bed Height
Range." Note – Adjusting machine to
accommodate 725 mm [28.5 inch] high boxes
also increases minimum box size to 170 mm
[6.8 inch].
Note - Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems,
or other electrical requirements compatible
with local practice.
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
BUMPER SUPPORTS (Upper Drive Assembly)
Raise and lock the upper drive assembly into its
raised position. See "Operation – Mechanical Latch."
Install the two bumper supports, one on each side
column using lower holes in bracket as shown in
Figure 2-6. (The upper set of holes allows the upper
drive assembly to return to a lower position.
However, this minimum position can only be used if
the taping heads are adjusted to apply 50 mm
[2 inch] long tape legs.)
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box and "On/Off" switch
are located on the lower left side of the machine
frame. See Figure 3-1. If desired, for operator
convenience, the "On/Off" switch can be
relocated to the right side of the machine frame.
A standard three conductor power cord with plug
is provided at the back of the electrical control
box for 115 Volt, 60 Hz., 3.8 Amp electrical
service. The receptacle providing this service
shall be properly grounded. Before the power
cord is plugged into 115 Volt, 60 Hz outlet make
sure that all packaging materials and tools are
removed from the machine. Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16 ], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
Note – Interference and damage to the taping
heads may occur if the upper mounting bracket
holes are used with the taping heads at the
standard setting (70 mm [2.75 inch] tape legs).
To reduce the risk associated with impact
hazards:
Always use appropriate supporting means
when working under the upper drive
assembly
WARNING
Figure 2-6 – Bumper Supports
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot and/
or vehicle traffic
WARNING