24
Maintenance (Continued)
Circuit Breaker
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical enclosure on the side of the
machine frame just below the machine bed, the
circuit breaker has been pre-set at 2.2 amps and
requires no further maintenance.
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Remove electrical enclosure cover.
3. Press "Reset" and then "Start" buttons on
circuit breaker. If circuit breaker will not
reset, wait 2 minutes and retry.
4. Replace cover.
5. Plug in machine.
6. Press machine "On" button to resume case
sealing.
Knife Replacement, Taping Head
See Section II, "Maintenance – Blade (Knife)
Replacement."
To reduce the risk associated with mechanical and electrical hazards:
Turn electrical and air supply off and disconnect before performing any adjustments, maintenance or
servicing the machine or taping heads
WARNING