Installation and
11.Box size capacity (height) – at its factory setting, the case sealer handles box sizes up to 620 mm
12.Drive Belt Height – drive belt assemblies can be raised 50 mm [2 inches] to provide better conveying of tall boxes. Refer to "Special Set- Up Procedure – Changing Drive Belt Height".
13.Pneumatic connection.
depressed and that all packaging materials and tools are removed from the machine. Do not plug electrical cord into outlet until ready to run machine.
Note – Machines outside the U.S. may be equipped with 220/240 Volt, 50 Hz systems, or other electrical requirements compatible with local practice.
WARNING
•To reduce the risk associated with mechanical and electrical hazards:
−Turn electrical and air supply off and disconnect before performing any adjustments, maintenance or servicing the machine or taping heads
The case sealer requires a 6.5 bar gauge pressure [95 PSIG] 75 liter/min @21°C, 1.01 bar [2.5 SCFM] compressed air supply. As shown in Figure
The main air supply line should be connected to the on/off valve by means of the barbed fitting and hose clamp provided on the outer side of the on/off valve as shown in Figure
If another type of connector is desired, the fitting can be removed and replaced with the desired
Always turn the valve "Off" when air supply line is being connected or disconnected.
14.Electrical connection and controls – the electrical control box shown in Figure
Initial Start-Up of Case Sealer
After completing the
Figure 2-5 – Pneumatic Connection
15