3M 800af-s Maintenance Continued, Air Line Filter – Figure, Circuit Breaker, 5– Air Line Filter

Models: 800af-s

1 98
Download 98 pages 20.27 Kb
Page 37
Image 37
Air Line Filter – Figure 4-5

Maintenance (Continued)

Circuit Breaker WARNING

To reduce the risk associated with mechanical and electrical hazards:

Turn electrical and air supply off and disconnect before performing any adjustments, maintenance or servicing the machine or taping heads

Air Line Filter – Figure 4-5

 

Periodically check the air line filter to drain water and

 

clean as necessary. Do not allow water to go above

 

the filter element.

 

Circuit Breaker

 

The case sealer is equipped with a circuit breaker

 

which trips if the motors are overloaded. Located

 

inside the electrical control box on the side of the

 

machine, the circuit breaker has been pre-set at

 

2.2 Amps and requires no further maintenance.

 

WARNING

 

To reduce the risk associated with

 

mechanical and electrical hazards:

 

– Allow only properly trained and qualified

 

personnel to operate and/or service this

 

equipment

 

If circuit is overloaded and circuit breaker trips,

Figure 4-5 – Air Line Filter

 

unplug machine from electrical power:

 

1. Determine cause of overload and correct.

2. Remove electrical enclosure cover.

3. Press the red "Reset" button and then the green "Start" button.

4. Replace cover.

5. Plug in machine. Wait two minutes.

6. Press machine "On" button, on the side guard, to resume case sealing.

Knife Replacement, Taping Head

See Section II, "Maintenance – Blade (Knife)

Replacement".