Troubleshooting (Continued)

Troubleshooting Guide

 

 

Problem

Cause

Correction

 

 

 

Flap kicker kicks at wrong time

Kicker cam improperly set

Reposition kicker cam

 

Air cylinder flow controls out of

Readjust flow controls

 

adjustment

 

 

 

 

Gate does not raise to stop next

Too much air pressure on gate

Reduce gate air pressure using

box

cylinder lifts box off of gate cam

regulator

 

Incoming boxes not low enough

 

 

and therefore not actuating cam

 

 

 

 

Gate retracts too soon/kicker does

The removable portion of the gate

Reinstall removable gate cam

not kick

cam has been removed and boxes

portion

 

shorter than 12 inches are being

 

Two boxes are taped together

run

 

 

 

 