52

Appendix A

Measurements

Types

Displayed Data and

SPL, Average value (Lavg or Leq), Maximum value (Lmx), Minimum value (LMn),

status indicators

Peak Value (Lpk), Exposure, Run Time, TWA, UL Time

Measurement parameters

Dosimeters

Two dosimeters at once (eg4), each with its own assignable profile (via

 

DMS only).

RMS Range

70 to 140 dB

RMS Weighting

A or C weighting

RMS Time Response

Fast or Slow

Exchange Rate (ER)

3 dB, 4 dB, or 5 dB

Peak Range

110 dB to 143 dB

Peak Weighting

C or Z weighting

Criterion Levels

70 to 90 dB in 1 dB increments

Threshold

70 to 90 db in 1 dB increments

Upper Limit (UL)

70 to 140 dB in 1 dB increments

053-644, Rev H

Page 52

eg4

Page 58
Image 58
3M eg4 user manual Measurements, Types, Measurement parameters