A.8 Serial Inferface Command Codes (continued)

Function

Code

Meaning

 

IR receiver selection

Write Codes

 

 

 

D5AW00

Selects Front and Rear IR Receiver

 

D5AW01

Selects Front IR Receiver

 

D5AW02

Selects Rear IR Receiver

 

Read Codes

Returns:

 

 

D5AR

00-Front and Rear Receiver is selected

 

 

01-Front receiver is selected

 

 

02-Rear receiver is selected

 

 

 

 

Magnify

Write Codes

 

 

 

D5BW00

 

 

 

D5BW01XY to

01:x1, 02:x2, 03:x4, 04:x8, 05:x16, 06:x32, 07:x64

 

D5BW07XY

XYdenotes magnifying portion (00 to FF)

 

Read Codes

 

 

 

D5BR

00 – Off

 

 

 

01 to 07

 

 

 

 

 

PIP

Write Codes

 

 

 

D5CW00

Off

 

 

D5CW01

ON1

 

 

D5CW02

ON2

 

 

D5CW03

Refreshes the background for ON1

 

Read Codes

Returns:

 

 

D5CR

00 – Off

 

 

 

01 – ON1

 

 

 

02 – ON2

 

Lamp Timer Reset

Write Codes

 

 

 

D60W00

Resets the lamp timer

 

Read Codes

Returns:

 

 

D60R

xxxx-shows lamp operating time in hours (decimal)

Temperature

Read Codes

Returns:

 

 

D61R

Shows the status of internal temperature

 

 

00-Temperature

level 0

 

 

01-Temperature

level 1

 

 

02-Temperature

level 2

 

 

03-Temperature

level 3

 

 

04-Temperature

level 4 (Warning)

 

 

05-Temperature

level 5 (Power Off)

 

 

 

 

Error Status

Read Codes

Returns:

 

 

D01R

00-No error

 

 

 

01-Interlock error

 

 

02-Lamp error

 

 

 

04-Temperature error

 

 

08-Fan error

 

 

 

10-Memory error

 

 

 

Note: If there is more than one error, the resulting read code will be the sum

 

 

f the error codes listed above. Example: For Interlock-01 and Lamp-02,

 

 

resulting read code is 03.

 

 

 

 

TECHNICAL

A-14

3MMultimedia Projector MP8780

© 3M 1999

Page 37
Image 37
3M MP8780 manual D5BW07XY