A.O. Smith 184769-000 owner manual Installation, Required Ability, General, Location of Heater

Models: 184769-000

1 12
Download 12 pages 15.57 Kb
Page 4
Image 4

INSTALLATION

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY, VENTING AND GAS SUPPLY ARE REQUIRED.

GENERAL

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the latest editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The code is available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131.

LOCATION OF HEATER

When installing the heater, consideration must be given to proper location. Location selected should be as close to the stack or chimney as practicable with adequate air supply and as centralized with the water piping system as possible.

The heater is design certified for installation on combustible flooring in a closet having minimum clearances from combustible material of: 1" clearance from sides and rear, 4" from the front and 18" from the top. (Standard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on heater.

A minimum clearance of 4" must be allowed for access to replaceable parts such as the thermostats, drain valve and relief valve.

Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. Minimum clearances for proper operation are given above.

CAUTION

WARNING

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California's Office of the State Architect, 400 P Street, Sacramento, CA 95814.

AIR REQUIREMENTS

WARNING

FOR SAFE OPERATION PROVIDE ADEQUATE AIR FOR COMBUSTION AND VENTILATION. AN INSUFFICIENT SUPPLY OF AIR WILL CAUSE RECIRCULATION OF COMBUSTION PRODUCTS RESULTING IN AIR CONTAMINATION THAT MAY BE HAZARDOUS TO LIFE. SUCH A CONDITION OFTEN WILL RESULT IN A YELLOW, LUMINOUS BURNER FLAME, CAUSING CARBONING OR SOOTING OF THE COMBUSTION CHAMBER, BURNERS, AND FLUE TUBES AND CREATES A RISK OF ASPHYXIATION.

Where an exhaust fan is supplied in the same room with a heater, sufficient openings for air must be provided in the walls.

UNDERSIZED OPENINGS WILL CAUSE AIR TO BE DRAWN INTO THE ROOM THROUGH THE CHIMNEY, CAUSING POOR COMBUSTION. SOOTING MAY RESULT IN SERIOUS DAMAGE TO THE HEATER AND RISK OF FIRE OR EXPLOSION.

DO NOT OBSTRUCT THE FLOW OF COMBUSTION OR VENTILATING AIR.

REFER TO THE LATEST EDITION OF THE “NATIONAL FUEL GAS CODE” ANSI Z223.1/NFPA 54.

In cold climates provide protection against freeze-up. THE HEATER SHOULD BE LOCATED IN AN AREA WHERE LEAKAGE OF THE TANK OR CONNECTIONS WILL NOT RESULT IN DAMAGE TO THE AREA ADJACENT TO THE HEATER OR TO LOWER FLOORS OF THE STRUCTURE. When such locations cannot be avoided, a suitable drain pan should be installed under the heater, see fig. 1. The pan must not restrict combustion air flow. Such pans should have a minimum length and width of at least 2 inches greater than the diameter of the heater and should be piped to an adequate drain. Drain pans suitable for these heaters are available from your dealer or A. O. Smith Water Products Company, 5621 W. 115th Street, Alsip, Illinois 60803.

WARNING

DO NOT INSTALL THIS WATER HEATER DIRECTLY ON A CARPETED FLOOR. A FIRE HAZARD MAY RESULT. Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches (76.2mm) in any direction. If the heater is installed in a carpeted alcove or closet, the entire floor shall be covered by the panel. Also, see the drain requirements.

Vapors from flammable liquids may explode and catch fire causing death or severe burns.

Do not use or store flammable products such as gasoline, solvents or adhesives in the same room or area near the water heater.

Keep flammable products:

1.far away from heater,

2.in approved containers,

3.tightly closed and

4.out of children’s reach.

Installation:

Do not install water heater where flammable products will be stored or used unless the main burner and pilot flames are

Water heater has a main burner and pilot flame.

The pilot flame:

1.is on all the time and

2.will ignite flammable vapors.

Vapors:

1.Cannot be seen,

2.are heavier than air,

3.go along way on the floor and

4.can be carried from other rooms to the pilot flame by air currents.

at least 18" above the floor. This will reduce, but not eliminate, the risk of vapors being ignited by the main burner or pilot flame.

4

Page 4
Image 4
A.O. Smith 184769-000 owner manual Installation, Required Ability, General, Location of Heater, AIR Requirements

184769-000 specifications

A.O. Smith 184769-000 is a notable water heater model that epitomizes efficiency and reliability in the realm of home appliances. As part of A.O. Smith’s comprehensive line of water heating solutions, this product showcases cutting-edge technologies and features that cater to contemporary household demands.

One of the standout characteristics of the A.O. Smith 184769-000 is its impressive energy efficiency. It is designed to minimize energy consumption while maximizing performance. The unit utilizes advanced insulation technology that reduces heat loss, ensuring that the water maintains its temperature even when the heater is not in active use. This feature not only contributes to lower energy bills but also promotes sustainability by reducing the carbon footprint associated with energy production.

The A.O. Smith 184769-000 incorporates high-quality components that guarantee long-lasting durability. The tank is crafted from robust materials that resist rust and corrosion, extending the life of the appliance. Coupled with the manufacturer’s industry-leading warranty, homeowners can enjoy peace of mind with the knowledge that they are investing in a product built to last.

In terms of capacity, this model offers various sizes to suit the needs of different households, whether for small families or larger homes. The water heater provides sufficient hot water supply to meet daily needs, from showering and cooking to laundry and dishwashing.

Another significant feature of the A.O. Smith 184769-000 is its intuitive digital interface. Users can easily adjust settings, monitor performance, and receive alerts for maintenance or issues through this user-friendly display. This technology allows for better control over the heating process, ensuring that households can enjoy hot water when they need it most.

The safety features integrated into the A.O. Smith 184769-000 are also commendable. It includes sophisticated over-temperature protection and a pressure relief valve, safeguarding the unit's operation and preventing potential hazards.

In summary, the A.O. Smith 184769-000 stands out for its energy efficiency, durable construction, user-friendly digital controls, and robust safety features. These characteristics make it a reliable choice for any homeowner looking to enhance their hot water supply system. Whether upgrading an existing unit or installing a new water heater, this model is engineered to meet and exceed expectations.