IP Phone Release Notes 2.0.2

Enhancements/Changes in 2.0.2, Build 1040

Issue Number

Description of Feature/Enhancement

 

 

DEF04929

Pressing a speeddial key while on an active call no longer places that call on hold.

 

When there is an active call, the speeddial key now sends DTMF digits through the

 

active voice path. For example, if you are on an active call, and a speeddial key is

 

configured on a different line to access your voicemail, you must put the active call

 

on hold and then press the speeddial key to access your voicemail on the other line.

DEF05224

The “Action URI Registered” is now executed on the first successful registration of

 

each unique line configured on the phone.

DEF05722

Increased the length of the stuttered dial tone used to indicate message waiting.

 

 

DEF05964

Usernames containing dots (“.”) are now supported.

 

 

ENH05637

The IP phones no longer support the alpha character in the password.

 

Non-numeric passwords are ignored in release 2.0.2 and all subsequent releases.

 

The default password is used instead.

ENH06153

Allow Barge In Feature

 

A User and Administrator can now configure a “barge-in” feature on the phone.

 

A new parameter has been added (“sip intercom allow barge in”) which controls

 

how the phone handles an incoming intercom call when an active call is in progress.

 

When you enable this parameter (1 = enable), which is the default value, an

 

incoming intercom call takes precedence over any active call, by placing the active

 

call on hold and automatically answering the intercom call. When you disable this

 

parameter (0 = disable), and there is an active call, the phone treats an incoming

 

intercom call like a normal call and plays the call warning tone.

 

An Administrator can set this parameter using the configuration files (sip intercom

 

allow barge in) or the Aastra Web UI (Allow Barge In at Basic

 

Settings->Preferences->Incoming Intercom Settings). A User can set this parameter

 

using only the Aastra Web UI.

 

Allow Barge In (in Web UI) (Default is enabled.)

 

 

 

ENH06301

REFER-TO header now uses uppercase characters in escape codes.

 

 

 

 

 

 