MPC-LNK
MPCLNK is a network board with an objective of sharing memory data and bit-unit information. By using MPCLNK, connected equipment (personal computers and MPC-68K) can share 249-byte memory. Also, because a function is included for transferring data by block to a specified address, individual communications that used to be performed by RS-232C etc. are supported together by MPCLNK. The number of connectable units is up to 16. When MPCLNK and LNK-048 are combined, one unit of MPCLNK and up to 15 units of LNK-048 are connectable.
The response speed is within 10 msec for transferring a shared variable from #1 to any other, and is the number of connection * 10 msec for changing a shared variable of #2-#15 except #1 or for the input status of LNK-048 to be returned to #1. In the case of up to five-unit connection which is a default factory ship- out condition, the response speed is within 50 msec.
As for the distance of the communication cable, because it is based on RS-485 standard, the connection will have no problem up to several hundred meters. Also, the communication interface is isolated by a pulse transformer, preventing noise trouble etc. that occurs when used by different power sources.
Because MPCLNK adopted an interface based on RS-485, it can be easily connected via twisted-pair cables. Two connectors and a short pin for a terminator belong to MPCLNK, and they are connected as in the figure. What should be kept in mind is for the connection to be in a cascade as in the figure and to set the terminator ON (the short pin is shorted) for the MPCLNKs at the ends.
PC (AT, 98) + LNK-048
| PC- LNK |
LNK- 048 | Twisted pair |
|
MPC-68K + LNK-048
LNK-048
MPC-LNK MPC-68K
This is a remote IO for a personal computer. One LNK-048 is equipped with 24-point input and 24-point output, and can perform reading of input from the host side and control of the output port. The host needs one MPCLNK, and the I/O unit and MPCLNK are connected via a twisted-pair cable. Because communication is done through an RS-485 interface, connection of plural LNK-048 is simple by multiple-drop bus connections of a twisted pair. Control and reading of the IO are performed via the UMB area of the personal computer (this is because MPCLNK works as a memory installed in the UMB area). Writing into the UMB area is reflected as is by the output port of LNK-048, and the input content of LNK-048 is reflected as is by the specified memory of the UMB. Therefore, the I/O can be directly controlled using application software for DOS/WINDOWS etc.
LNK-048 is a remote IO of MPC-68K. One LNK-048 is equipped with 24- point input and 24-point output, and can perform reading of input from the 68K side and control of the output port. The host needs one MPCLNK, and the I/O unit and MPCLNK are connected via a twisted-pair cable. Because communication is done through RS-485 interface, connection of plural LNK- 048 is simple by multiple-drop bus connections of a twisted pair. For control and reading of IO, the IO commands such as ON/OFF, SW(), etc. of MPC- 68K are available.
LNK-048 + LNK-048
LNK- 048
By using LNK-048 one on one, the I/O condition can be transmitted as it is to a distant place. The 24-point input content to one is reflected by the output of the other. Connection of LNK-048 is by one twisted pair, withstanding even a distance of several hundred meters (in the case of an RS-485 standard cable). Also, if the IO link destination is fixed, two or more LNK-048 can be IO-connected (customization
LNK- 048 | will be necessary). |
|