Acer 6492 manual Battery and Charger, Power Control Pin Description, State Output Pin

Models: 6492

1 190
Download 190 pages 60.17 Kb
Page 53
Image 53

Hibernate(S4)

 

(8)

 

 

 

 

 

 

 

 

 

 

 

Soft Off(S5)

 

(9)

 

 

 

 

 

 

 

 

 

 

 

Mechanical off is a condition where all power except the RTC battery has been removed from the system.

1.Initial to On state: When the AC adapter or Battery pack has been plugged into the system, the PC97551 will be reset and initial all output pins then the system goes into Initial state and waiting for power on event. If the power button is pressed then the system will go into the ON state.

2.ON to Standby state: The system will go into the Standby state when 963L receives the POS command.

3.ON to Suspend state: The system will go into Suspend state when SB460 receives the S2R command.

4.ON to Hibernate state: The system will go into Hibernate state when SB460 receives the S2D command.

5.ON to Soft Off state: The system will go into Soft Off state when SB460 receives the Soft off command.

6.Standby to ON state: The system will go into ON state when the system receives any wake up events, for example, power button, Lid switch.

7.Suspend to ON state: The system will go into ON state when the power button is pressed.

8.Hibernate to ON state: The system will go into ON state when the power button is pressed.

9.Soft Off to ON state: The system will go into ON state when the power button is pressed.

Power Control Pin Description

The following table is NS PC97551 power control pin description:

State

 

 

Output Pin

 

 

 

 

 

 

 

 

S5_ON

3VAUXEN

 

SUSON

MAINON

VRON

 

 

 

 

 

 

 

 

 

Initial

0

0

 

0

0

0

 

 

 

 

 

 

 

ON(S0)

1

1

 

1

1

1

 

 

 

 

 

 

 

Standby(S1)

1

1

 

1

1

1

 

 

 

 

 

 

 

Suspend(S3)

1

1

 

1

0

0

 

 

 

 

 

 

 

Hibernate(S4)

1

1

 

0

0

0

 

 

 

 

 

 

 

Soft Off(S5)

1

0

 

0

0

0

 

 

 

 

 

 

 

Battery and Charger

Current Amplifier: MAX8724

Charge PWM Control: IMD2AT108

PARAMETER

CONDITIONS

MIN

TYP

MAX

UNITS

 

 

 

 

 

 

Min Input Range

VA

18

19

20

V

 

 

 

 

 

 

Input Low Voltage

M/A-, D/C-, BL/C-, REFON

 

 

0.8

V

 

 

 

 

 

 

Input high Voltage

M/A-, D/C-, BL/C-, REFON

2.5

 

5.5

V

 

 

 

 

 

 

Charge Voltage

CV-SET =0V

15.93

16.09

16.25

V

 

 

 

 

 

 

Charge Voltage

CV-SET =5V

16.95

17.11

17.27

V

 

 

 

 

 

 

Charge Current

CC-SET =0.5V (for Li -ion)

0.1

0.25

0.4

A

 

 

 

 

 

 

Charge Current

CC-SET =5V (for Li-ion)

3.73

3.93

4.13

A

 

 

 

 

 

 

Charge PWM Frequency

 

 

200

 

KHz

 

 

 

 

 

 

Efficiency

VA=19V Output 12V/1.7A

 

91

 

%

 

 

 

 

 

 

3-13.1. DC to DC Converter

TI TPS51120 PWM chip: 5V & 3.3V &15V

PARAMETER

CONDITIONS

MIN

TYP

MAX

UNITS

 

 

 

 

 

 

5V

Current 0-3A

4.8

5.0

5.2

V

 

 

 

 

 

 

3.3V

Current 0-3A

3.14

3.35

3.76

V

 

 

 

 

 

 

Chapter 1