GARANTIA COMPLETA DE UN (1) AÑO

9. Llevar a cabo los pasos 1 a 8 para el sistema de avance centrífugo si es que todavía no se ha hecho.

10.Apagar el motor y conectar la bomba de vacío externa al diafragma de vacío en el distribuidor o a la computadora a bordo del vehículo.

11.Poner el control de avance de la luz de regulación en “0”. Volver a arrancar el motor.

12.Apuntar la luz de regulación a las marcas de regulación, pulsar el gatillo y observar la regulación del motor.

13.Ajustar la velocidad (rpm) del motor si es necesario, y aplicar los niveles de vacío al diafragma de vacío del avance, como se indica en el manual de servicio del vehículo. (Si es necesario reajustar las rpm del motor según las instrucciones del manual de servicio del motor, observar nuevamente la regulación del motor como se indica en el paso 12).

14.Girar el control de avance de la luz de regulación hacia arriba hasta que la marca de regulación en el motor regrese a su punto de partida, como se observó en el paso 12.

15.Observar el avance de regulación (en grados) con cada aplicación de vacío y comparar el resultado con los valores dados en el manual de servicio. Si no se logra obtener las lecturas del avance de vacío podría significar fugas en el diafragma, mecanismo de avance pegajoso, o ausencia de

GARANTIA COMPLETA DE UN (1) AÑO

Actron Manufacturing Company, 15825 Industrial Parkway, Cleveland, Ohio 44135, garantiza al usuario que este equipo estará libre de defectos en los materiales y fabricación por un período de un (1) año a partir de la fecha de compra original.

Cualquier equipo que llegue a fallar dentro de este período será reparado o reemplazado a entera discreción de ACTRON y sin cargo cuando sea devuelto a la fábrica. ACTRON solicita que junto con el equipo se envíe una copia de la boleta de venta original fechada, si el período de garantía todavía está en efecto.

Esta garantía no cubre los daños causados por accidente, modificaciones o el uso inapropiado o irrazonable. Los componentes de duración limitada, por ej., baterías, fusibles, bombillas de luces, tubos destellantes, quedan excluidos del amparo de esta garantía.

ACTRONS PRODUCTS NO SE

RESPONSABILIZA POR DAÑOS FORTUITOS O EMERGENTES DEBIDO AL INCUMPLIMIENTO DE CUALQUIER GARANTIA ESCRITA SOBRE ESTE EQUIPO. Algunos estados no aceptan el rechazo de responsabilidad por daños fortuitos o emergentes, por lo tanto esta negación de responsabilidad puede no servir en el caso suyo. Esta garantía otorga derechos legales específicos, y también pueden existir derechos que varía de un estado a otro.

 INSTRUCTIONS INSTRUCCIONES EN ESPAÑOL INSTRUCTIONS INTRODUCTIONInductive Timing Light

INSTRUCCIONES EN ESPAÑOL

Vea la pagína 9

INTRODUCTION

Precise ignition timing is essential to achieve maximum fuel economy and performance out of any spark ignited engine. Your timing light provides a simple method for timing the en- gines used in today’s vehicles. The advance timing light provides the additional capability of allowing the user to check timing advance curves of the vacuum, mechanical or com- puter controlled types.

Virtually all engines require that timing, both initial and advance calibrations be set, or checked at specific engine speeds, or in some cases with a specific vacuum applied to the vacuum advance diaphragm on the distribu- tor, or on the vehicle’s on-board computer. Your supplier offers a number of engine ana-

Inductive Timing Light

Inductive Advance Timing Light

D. C. Powered Timing Light

lyzers which are capable of measuring engine RPM, and vacuum pumps for application of vacuum when required. Contact him for further information on these instruments. In the case of engines which are equipped with breaker point ignition systems, it will be necessary to check and, if necessary, adjust point dwell before adjusting timing. Make certain that the instrument that you have or intend to purchase has dwell measurement capability.

Metal cased timing lights are for use on twelve

(12)volt negative (-) ground systems only. Plastic cased timing lights may be used on six

(6)or twelve (12) volt, positive (+) or negative (-) ground systems by following the simple instructions in this manual.

vacío para accionar el diafragma del motor de vacío.

16.Después de completar todas las pruebas, asegurar de reajustar las velocidades en vacío y reconectar las mangueras o conectores eléctricos que fueron desconectados durante el procedimiento de prueba.

IMPORTANT

CONSULT THE VEHICLE SERVICE MANUAL FOR SPECIFIC TUNE-UP INFORMATION AND TEST PROCEDURES. ALWAYS FOLLOW THE MANUFACTURER’S SPECIFICATIONS AND TEST PROCEDURES FOR ADJUSTING DWELL ANGLE AND IDLE SPEED, ESPECIALLY ON VEHICLES WITH MODERN ELECTRONIC IGNITION AND EMISSION CONTROLS. DO NOT ATTEMPT TO SERVICE A VEHICLE WITHOUT THE MANUFACTURER’S INSTRUCTIONS AND SPECIFICATIONS.

VEHICLE MANUAL, SOURCES FOR SERVICE INFORMATION

The following is a list of publishers who have service manuals for your specific vehicle at nominal cost. Write to them for availability and prices, specifying the make, style, and model year of your vehicle.

©1996 ACTRON MANUFACTURING CO.

0002-000-219201

15825 Industrial Parkway

 

PRINTED IN U.S.A.

Cleveland, Ohio 44135

16

American Motors Corporation

Buick

OTHER SOURCES- Nonfactory

Myriad

Tuar Company

 

8835 General Drive

Post Office Box 354

Domestic and Import Cars

Plymouth Township, MI 48170

Flint, MI 48501

Chilton Book Company

 

 

Chilton Way

Chrysler Corporation

Oldsmobile

Radnor, PA 19089

Dyment Distribution Service

Lansing Lithographers

 

Service Publication

Post Office Box 23188

Cordura Publications

20770 Westwood Drive

Lansing, MI 48909

Mitchell Manuals, Inc.

Strongsville, OH 44136

 

Post Office Box 26260

 

Cadillac, Chevrolet, Pontiac

San Diego, CA. 92126

Ford Publications Department

Helm Incorporated

 

Helm Incorporated

Post Office Box 07130

Motor’s Auto Repair Manual

Post Office Box 07150

Detroit, MI 48207

Hearst Company

Detroit, MI 48207

1

250 W. 55th Street

 

New York, NY 10019

Page 1
Image 1
Actron Inductive Timing Light service manual Inductive Advance Timing Light, D. C. Powered Timing Light, Introduction