3.Sprinkler System Component Replacement

a. Resistive Temperature Device (RTD) Replacement

1)Turn the water supply to the dryer off.

2)Discontinue electrical service to the dryer.

3)Remove the 1/4" compression fitting.

4)Remove the two (2) screws from the junction box cover.

5)Remove the wires of the RTD (Resistive Temperature Device) from the terminal strip.

NOTE: Identify the wires removed for proper reinstallation.

6)Loosen the cord grip cap.

7)Remove Resistive Temperature Device (RTD).

8)To install new RTD (Resistive Temperature Device), reverse above procedure..