c)Front Doors Closed circuit branch.

There are two (2) magnetic proximity switches mounted in the door closed position and a magnet mounted on top of the doors. When this magnet aligns with the proximity switch, the contacts in the proximity switch close. When both doors are closed, the front doors closed relay (CR2) turns on.

(1)There are two (2) sets of contacts in the relay...one (1) set of contacts are in the dry enable circuit branch and the other set go to the PLC (Programmable Logic Controller) input front doors closed.

d)Lint Drawer Closed circuit branch ...

The lint drawer closed switch is located in the front of the dryer. When the lint drawer is closed, it closes the switch contacts, powering the lint drawer closed relay. Then, the dry enable relay will close, supplying 24 VAC to the Phase 5 microprocessor (computer) door signal. This sequence will occur only if the following conditions are met;

(1)Blower (impellor/fan) Motor Overload is not tripped.

(2)Drive (tumbler/basket) Motor Overload is not tripped.

(3)Dryer is level.

(4)Lint Drawer is closed.

(5)Doors are closed.

b. Phase 5 Microprocessor Controller (computer)

1)The Phase 5 Microprocessor Controller (computer) is powered by 240 VAC on Pin #7 and Pin #13. A jumper wire on Pin #1 to Pin #11 is required to configure the Phase 5 microprocessor (computer) for 240 VAC. The temperature sensor probe is a bullet shaped device that is located above the lint basket. This temperature probe is used to sense the temperature in the exhaust of the dryer. The temperature sensor is a two (2) terminal monolithic integrated circuit temperature transducer that provides an output current proportional to absolute temperature. The transducer acts as a high impedance temperature dependant current source of 1mA/ºK. The typical accuracy of this probe is +/- 2.7º F (+/- 1.5º C). In a case where the temperature reaches 220º F (104º C), the Phase 5 microprocessor (computer) will shut down and the L.E.D. (light emitting diode) will display "Hot." To restart a cycle the "CLEAR/STOP" button must first be pressed.

ºF

=

9

(ºC + 32)

 

 

 

5

 

ºC + ºK (273.15)

 

 

 

 

TEMPERATURE SENSOR CURRENT

=

= MICROAMPHERES (∝ A)

 

 

5

1,000,000

ºC

=

(ºF - 32)

 

 

 

 

9

 

 

 

 

8 6

Page 90
Image 90
ADC AD-310 service manual ºc +