Chapter 2

INSTALLATION

When using the mounting bracket, allow six inches (15.3 cm) on both ends of the ENIU for cable access. Install the ENIU using the following procedures.

DESKTOP INSTALLATION

Step

Action

1Remove the protective adhesive backing from the four feet. Position a foot on each bottom corner of the ENIU. Press these firmly onto the ENIU.

2Situate the ENIU in a way that provides both front and rear access. LEDs and Ethernet connections are located on both ends. Power connection is located on the rear panel.

3Connect the power supply to the DC IN connector located on the back of the ENIU:

If using AC power, connect the power supply to the AC source (110 – 240 VAC, 50 – 60 Hz).

If using DC power, connect the power following local practices. (See “Power and Ground Connections” on page 2-2.) See Appendix A: Specifications for fuse size.

4Verify that the STATUS LED is lit.

DANGER

Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the

optical connector of an operational transmitter, or into the end of an active fiber. A clean,

 

 

protective cap or hood MUST be immediately placed over any radiating connector or optical fiber

 

to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent

 

contamination of connectors and adapters. Do not assume laser power is turned off or the fiber

 

is disconnected at the other end.

SURFACE MOUNT INSTALLATION

An optional ENIU mounting bracket provides a number of options when securing the ENIU to a vertical or horizontal surface. An ENIU can be installed facing up, down, right, or left when mounted on a vertical surface. The same mounting bracket is also used to secure the ENIU to the bottom of a work surface.

Note: Allow six inches (15.3 cm) on both ends of the ENIU for cable access.

Step

Action

1Situate the ENIU in a way that provides both front and rear access. LEDs and Ethernet connections are located on both ends. Power connection is located on the rear panel.

2Using the mounting bracket as a template, mark and drill holes in the mounting surface.

3Secure the mounting bracket to the surface with appropriate fasteners for the surface material (#10 wood screws or machine screws depending on the mounting surface).

4Align the slots on the rear face of the ENIU with the mounting bracket. See Figure 2-1. Slide the ENIU into the mounting bracket.

5If not already installed, insert SFP into ENIU until you hear it click in place.