AIWN-UM-7001-01 3-1
3
Chapter
COMMAND-LINE INTERFACE (CLI)
This section lists the commands used to operate the ENIU. After the initial installation of an ENIU, most testing and
local operations are conducted with the Command Line Interface through a VT-100 compatible terminal. This
terminal is connected to the front panel of the ENIU, and provides a standard EIA-232C interface.

COMMAND PROMPT

The CLI provides a prompt with a character indicating the user’s privilege level.
Table 3-1. CLI Command Prompts
SET-UP
The ENIU requires minimal set-up to provide OAM PDU reception, reporting, and remote loop-back functionality.
The ENIU is shipped with a power supply connector, and a serial communications cable. The user must provide
network cables (Cat5e or better Ethernet cables for electrical interfaces or optical cables appropriate to the SFP for
optical connections). A PC with HyperTerminal or equivalent is required with an available COM port for status
monitoring. Follow these steps to connect the unit:
Note: Command keywords are not case-sensitive.
Effective privilege Prompt
RO command $
RW command %
SECURE command #
Step Action
1 Connect Ethernet and/or optical cables to the desired equipment.
2 Connect the serial communications cable to the Command port of the ENIU and to any COM port on the
local PC.
3 Launch HyperTerminal and configure it for 115200 bits per second, 8 data bits, 0 parity bits, 1 stop bit,
and no flow control.
4 Connect the power supply to the appropriate connector on the ENIU.
5 Verify that the terminal displays a configuration screen.