Adder Technology SV2, SV4 manual Autoscan lock on mode and delay time

Models: SV2 SV4

1 34
Download 34 pages 40.83 Kb
Page 23
Image 23
4.3 Autoscan lock on mode and delay time

D1 - Display dot flashes to indicate activity, right handed auxiliary display (default) D2 - Display dot does not flash, right handed auxiliary display

D3 - Display dot flashes to indicate activity, left handed auxiliary display D4 - Display dot does not flash, left handed auxiliary display

D5 - Display dot flashes, auxiliary display port configured for monitor light module D6 - Display dot does not flash, auxiliary port configured for monitor light module

4.3 Autoscan lock on mode and delay time

SmartView can be set to select each channel in turn for a period of time set by the Autoscan delay time. Autoscan mode is entered by typing the hotkey keys together with ‘A’. By default, only those channels which have a powered up computer connected to them will be scanned. Sometimes it may be desirable to scan all channels, even if the attached computer is switched off (this will simply show a blank screen when it is selected). Computers 1 and 2 will be autoscanned on a 2 port SmartView and computers 1, 2, 3 and 4 on a 4 port switch if option L2 is selected. Some applications may also require the SmartView to power on in autoscan mode. This feature can be selected using the L3 or L4 options.

L1 - SmartView only locks on to active ports during autoscanning (default)

L2 - SmartView locks on to every port in turn during autoscanning

L3 - SmartView powers on in autoscan mode and locks on to active ports only L4 - SmartView powers on in autoscan mode and locks on to all ports

T1 - 2 seconds autoscan delay time before switching to next port (default) T2 - 5 seconds autoscan delay time before switching to next port

T3 - 7 seconds autoscan delay time before switching to next port

T4 - 10 seconds autoscan delay time before switching to next port T5 - 15 seconds autoscan delay time before switching to next port T6 - 20 seconds autoscan delay time before switching to next port T7 - 30 seconds autoscan delay time before switching to next port T8 - 60 seconds autoscan delay time before switching to next port

note: Autoscan mode is ended simply by selecting a fixed channel using the keypad, keyboard hotkeys or the mouse.

SmartView

Installation and Use

Page 22

Page 23
Image 23
Adder Technology SV2, SV4 manual Autoscan lock on mode and delay time