Adder Technology X2  , Video outputs, Twisted pair link connections, Link cable

Models: X2

1 31
Download 31 pages 16.43 Kb
Page 13
Image 13
Video outputs
SERIAL 1
2 Ensure that the other end of the twisted pair link connects to the corresponding numbered socket on the LOCAL module (labelled
TO REMOTE 1 to TO REMOTE 4).

Video outputs

You can connect multiple video monitors to the REMOTE module (up to two on the MS2 model or up to four on the MS4 model).

Twisted pair link connections

The links between the LOCAL and REMOTE modules are made using between one and four twisted pair cables, specified to Category 5 or higher.

1Attach the signal leads from each video monitor to the output sockets (labelled VIDEO OUT

1 to VIDEO OUT 4) on

the REMOTE module.

VIDEO

OUT

 

 

4

VIDEO

OUT

 

 

3

VIDEO

OUT

 

 

2

VIDEO

OUT

 

 

1

The various cable connections carry the following channel signals (if particular channels are not used, then corresponding link cables are not required):

Link cable

Channel signals carried

 

1

Keyboard, Mouse, Audio, Video 1, Serial 1

2

Video 2, Serial 2

3Video 3, Serial 3 (not MS2 model)

4Video 4, Serial 4 (not MS2 model)

IMPORTANT: Ensure that the total twisted pair cable length (including patch boxes) does not exceed 200 metres for any link cable. Ensure that the multiple link cables are all of the same length to avoid the risk of uneven delays on video images.

For each required link connection:

 

Connections from

REMOTE

 

monitors (two

 

outputs available

 

on MS2 model)

 

1Insert the connector from the twisted pair cable link into one of the sockets (labelled TO

TO

4

SERIAL

4

3

Serial cable connections You can attach multiple serial devices (such as touch screen inputs) to the remote module (up to two on the MS2 model or up to four on MS4 model).

Note: The links support software or hardware handshaking up to a maximum baud rate of 56Kb/s.

For each required serial connection:

1Connect the cable from the serial device to one of the

9 pin ports on the LOCAL

module (labelled to SERIAL 4).

2Ensure that the corresponding serial connection at the LOCAL module matches this device and the necessary port on the host system.

TO

LOCAL

 

 

4

 

 

TO

LOCAL

SERIAL4

 

 

TO

LOCAL

SERIAL3

 

2

 

 

SERIAL

 

 

2

TO

 

USEINDOOR

LOCAL

ONLY

 

 

1

 

 

 

 

SERIAL

 

 

1

 

 

PO

 

 

WER

REMOTE

Connections to serial devices (two outputs available on MS2 model)

LOCAL 1 to TO LOCAL 4).

 

SERIAL

 

3

 

2

 

SERIAL

 

2

TO

USEINDOOR

ONLY

 

 

1

 

SERIAL

 

1

 

PO

 

WER

twisted pair

connections -

cables must beREMOTE of equal lengths

      

12

Page 13
Image 13
Adder Technology X2  , Video outputs, Twisted pair link connections, Link cable, Channel signals carried