Adder Technology X2 manual Installation and operation, Stage A - Configuration switch settings

Models: X2

1 31
Download 31 pages 16.43 Kb
Page 6
Image 6
Installation and operation

Installation and operation

Installation

The installation of the X2 Multi Screen extenders is straightforward and can best be achieved in most cases by following these stages for each module:

Stage A

Check or set the configuration switch settings

Stage B

Mount the module

Stage C

Connect the cables

Stage A - Configuration switch settings

The basic operation of the LOCAL and REMOTE modules are controlled by the banks of four switches located on the side of each module. The switches are monitored at all times and may be changed when power is on or off (the only exception to this rule is switch 1 of the LOCAL module which initiates slightly different functions depending on the power state when it is switched).

LOCAL module switches

 

 

 

 

 

 

OFF: Normal operation

 

 

 

 

 

 

ON: Transparent mode

ON

1

 

 

 

OFF: Normal operation

2

 

ON: Reset LOCAL module

OFF: Normal operation

 

 

 

3

4

 

 

 

 

ON: Flash upgrade/reset

 

 

 

 

 

 

 

 

 

password modes

 

 

 

 

 

 

OFF: Microphone input mode

 

 

 

 

 

 

ON: Stereo line-in mode

 

 

 

 

 

 

N 1

 

 

 

 

 

O

 

2

 

 

 

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

Note: When shipped, all switches are set in the OFF positions and this will produce normal operation with normal microphone input (at the REMOTE module).

LOCAL module switches (continued)
LOCAL Switch 1

OFF: Normal operation.

ON: (Before power is applied) Places the LOCAL module into flash upgrade mode so that the internal software can be changed. Please see the ‘Flash upgrade’ section in the ‘Special configuration’ section.

ON: (Whilst power is applied) Places the REMOTE module into password override mode. This allows any pre-configured passwords to be altered

-particularly useful when they have been lost or forgotten. Please see the ‘Password override’ section in the ‘Special configuration’ chapter.

LOCAL Switch 2

OFF: Normal operation.

ON: Set transparent mode. Use this setting if the X2 Multi Screen modules are to be used with KVM switches that are not manufactured by Adder Technology. Cascaded KVM switches often use special signals to set or identify conditions. In transparent mode, the X2 Multi Screen modules will pass the signals without attempting to interpret them.

LOCAL Switch 3

OFF: Microphone input on REMOTE module. Use this setting if a standard mono- channel microphone is connected to the MIC input on the REMOTE unit.

ON: Stereo line-in input on REMOTE module. Use this setting if a stereo input is applied to the MIC input on the REMOTE unit.

LOCAL Switch 4

OFF: Normal operation.

ON: Suspend operation and reset the LOCAL module. Use this setting momentarily to produce the same effect as removing and restoring power if incorrect operation has occurred. Return the switch to the OFF position to allow normal operation to continue.

        

5

Page 6
Image 6
Adder Technology X2 manual Installation and operation, Stage A - Configuration switch settings, LOCAL module switches