Adder Technology X2 manual REMOTE module switches continued, , REMOTE Switch

Models: X2

1 31
Download 31 pages 16.43 Kb
Page 7
Image 7
REMOTE module switches

REMOTE module switches

 

ON

1

2

 

 

OFF: Normal operation

 

 

3

4

ON: Flash upgrade

 

 

 

 

 

 

 

Determines configuration of hotkeys in conjunction with switch 2

N 1

 

 

 

O

2

 

 

 

3

 

 

 

4

 

 

 

Determines configuration of hotkeys in conjunction with switch 3

Reserved for future use

REMOTE module switches (continued)

REMOTE Switch 1

OFF: Normal operation.

ON: (Before power is applied) Places the REMOTE module into flash upgrade mode so that the internal software can be changed. Please see the ‘Flash upgrade’ section in the ‘Special configuration’ chapter.

REMOTE Switches 2 and 3

Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as ‘hotkeys’. Hotkeys signal to the REMOTE module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system.

2 OFF

 

3 OFF

Hotkeys = CTRL and SHIFT



Note: When shipped, all switches are set in the OFF positions and this will produce normal operation.

2

OFF

 

3

ON

Hotkeys = ALT and SHIFT

2 ON

 

3

OFF

Hotkeys = CTRL and ALT

2 ON

 

3

ON

Hotkeys disabled

REMOTE Switch 4

This switch is reserved for future use.

       