Version 3.10E DAS Release Notes 21
21 Dec 2001
Corrections in DAS 3.10E
Addressed Problem Logs
Table 5 Problems solved with DAS 3.10E
Ticket
Number Description
ET60330 "Cleanpool with 16 chars doesn't work". There is a
bug with incorrect setting of field value in AMU
telegram, which will be fixed.
In dasadmin "scr_insert" command another aci
function with a larger buffer size for volsers can
be used. The old aci function (aci_insert()) might
have a problem with large EIF and double-sided
(optical) volsers.
ET56507 "DAS/ACI timeout to 1st server when network is
down". The ability of preliminary testing of
connection with DAS server has been added. If
DAS/2 and ACI clients will be started with the
PORT_PING=<port> environment variable set
then this ability will be activated.
ET33777 "Eject has limited number of volsers".
"eject2" command in dasadmin has a limited buffer
size for volsers (100 bytes).
Now the "eject3" command is similar to "eject2" but
has a buffer size of 512 bytes.
PR97 "Mount failed after issued PINVT". There is a bug
in the DAS code, related to improper handling of
RPC task number. Will be fixed.
"Scr_set command works wrong". There is a bug
causing improper handling of media types in the
"scr_set" branch. This prohibited users from
inserting cartridges in scratch pool if the use count
of cartridges was not equal to zero.
PR82 "DAS:allocv: The manual says that a check of the
Volser in the given range will be made as to one is
available or mounted". DAS doesn't check the
availability of the requested volser and could
return a positive answer for a mounted volser. Will
be fixed.