Quick Turn-up Steps

61179621L1-5C 3-19

8. The T1 Main Menu (see Figure 3-14) displays.Figure 3-14. T1 Main Menu9. From the T1 Main Menu, select T1 Provisioning, and press ENTER.The T1 Provisioning menu (see Figure 3-15) displays.Figure 3-15. T1 Provisioning Screen
TID: HSVL00001 Total Access 1224 MM/DD/YY HH:MM
Unacknowledged Alarms: None
T1 Main Menu
1. T1 Provisioning
2. T1 Status
3. T1 Performance
4. Test
5. Restore T1 Factory Defaults
Selection :
'?' - System Help Screen
TID: HSVL00001 Total Access 1224 MM/DD/YY HH:MM
Unacknowledged Alarms: None
T1 Provisioning for # 1
1. Type DSX
2. Framing ESF
3. Line Code B8ZS
4. Line Build Out 0 - 133 ft
'N' - Next T1 Port 'P' - Previous T1 Port
Selection :
'?' - System Help Screen