Total Access 1224 Quad T1 IMA 24-Port DSLAM Installation and Maintenance Practice
5-42 61179621L1-5C
Inband OAM Loopback Test Menu
Inband OAM Loopback Test
Main Menu\ATM Circuit Management\ATM OAM S etti ngs\Inband OAM Loopback Test\
The Inband OAM Loopback Test menu (see Figure 5-28) is used to provision the Total Access 1224 OAM Loopback settings and to test the Inband channel PVC for an ATM fed box. Figure 5-28. Inband OAM Loopback Test MenuThe Inband OAM Loopback Test menu options are shown in Table 5-26.Table 5-26. Inband OAM Loopback Test Menu Options
Option Description Function
1Remote OAM Loopback
Location ID
This is option is used to enter the remote loopback
location ID. The remote loopback location ID is in
hexadecimal 16 byte format.
2Type of OAM Loopback Cell This option is used to specify the type of OAM Loopback
cell. Options include the following:
•Segment
•End-to-End
3Send Loopback Cell This option is used to send a loopback cell.
4Reset Loopback Statistics This option clears the OAM loopback statistics for this
circuit.
5Reset All Statistics This option clears all OAM loopback statistics.
TID: HSVL00001 Total Access 1224
Unacknowledged Alarms: None
Inband OAM Loopback Test
Port VPI VCI
0 0 32
Tx Loopback Request : 0 Rx OAM Cells : 0
Rx Loopback Request : 0 AIS State : FALSE
Tx Loopback Response : 0 RDI State : FALSE
Rx Loopback Response : 0
Loopback Passed : 0
Loopback Failed : 0
1. Remote OAM Loopback Location ID : FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
2. Type of OAM Loopback Cell : Segment
3. Send Loopback Cell
4. Reset Loopback Statistics
5. Reset All Statistics
Selection :
'?' - System Help Screen