Protection Configuration Screen
The protection configuration screens (Figure 21 and
22)provides status and control details for fault protected circuits.
NOTE
The screens provided below are typical and may vary slightly depending on the hardware installed. For Instance, if HDSL2
11/23/99 | 00:32:51 |
| PROTECTION | CONFIGURATION |
|
| SHELF ADDRESS = 00 | |||||||
|
|
|
|
| [ SLOT 2 | ] |
|
|
|
|
|
|
| |
|
| ________________________________________________ |
|
| ||||||||||
|
| PROTECTION OPTIONS |
| CURRENT SETTINGS |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 1. BER THRESHOLD | = |
|
|
|
|
| ||||||
|
| 2. BER INTERVAL | = | 15 MINS |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| ________________________________________________ |
|
| ||||||||||
|
|
| MAIN CARD CAN ONLY SET THE BER OPTIONS. |
|
|
| ||||||||
|
|
| SHELF STATUS |
|
|
|
|
| ||||||
SLOT | 01 02 | 03 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | |||
STATUS | ** | ** |
| ** | ** | ** | ** | ** | ** | ** |
_____________________________________________________________________________
MAIN | ACTIVE | ACTIVE | ** | = STANDARD | ||||
Press: | “nnS” - select | slot, | “nP” - select | option, |
| |||
| “M” | - main menu, “I” | - | implement and | save | current changes : |
Figure 21. Protection Screen (Main)
11/23/99 | 00:29:33 | PROTECTION CONFIGURATION | SHELF ADDRESS = 00 | |||||
|
|
| [ | SLOT 3 | ] |
|
|
|
| _____________________________________________________________________________ |
| ||||||
PROTECTION OPTIONS | CURRENT | SETTINGS | SWITCHOVER HISTORY | |||||
|
| |||||||
1. | PROTECTION MODE | = AUTO |
| SWITCHOVERS | ||||
2. | MINIMUM HOLDIN TIME | = 01 | MIN(S) | REVERSIONS | ||||
3. | BER THRESHOLD | = |
| FAILURES | ||||
4. | BER INTERVAL | = 15 | MINS | LOCKOUTS | ||||
5. | LOCKIN HOURS | = 12 | HR(S) |
|
| |||
6. | SWITCH TO AUX LIMIT | = 09 |
|
| ||||
7. | LOCKIN CHECK INTERVAL = 20 | MIN(S) |
|
|
____________________________________________________________________________
| LOCKIN | OPTIONS: | IF 09 SWITCHOVERS OCCUR IN 20 MINUTES, | LOCKIN FOR 12 HOURS. |
| |||||||||||
| SYSTEM | CURRENT STATUS | : NORMAL OPERATION |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| SHELF STATUS |
|
|
|
| ||||||
| SLOT | 01 | 02 | 03 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | |||
| STATUS |
| ^^ | ** |
| ** | ** | ** | ** | ** | ** | ** |
_____________________________________________________________________________
MAIN | ACTIVE | ACTIVE | ** | = STANDARD | ||||
Press: | “nnS” - select | slot, | “nP” - select | option, |
| |||
| “M” | - main menu, “I” | - | implement and | save | current changes : |
Figure 22. Protection Screen (Aux)
|