interconnect subsequent shelves. Each shelf controller should be assigned unique sequential shelf addresses. No connection should be made to the RS422 in connector on the shelf containing the E220 HCOT-CTL.

4. FACEPLATE FEATURES

The terminal interface operates at a data rate range of

4.8kbps to 19.2 kbps. The asynchronous data format is fixed at eight data bits, no parity, one stop bit. The supported terminal type is VT 100, or compatible.

Optional terminal parameters should be set as follows:

Table 6 defines the faceplate features of the HFAC.

5. CONTROL PORT OPERATION

The HFAC provides a faceplate-mounted DB9 connector which supplies an RS232 interface for connecting to a controlling terminal. Pin assignments are shown in Figure 6.

DSR

6

1

 

2

TXD (TXD to DTE)

RTS

7

3

RXD (TXD from DTE)

CTS

8

4

DTR

 

9

 

5

SGN GND

 

 

Figure 6. Control Port Pin Assignments

(DCE Configuration)

¥XON/XOFF flow control

On

¥TX carriage return

<CR> (not <CRLF>)

¥Send ACK*

Off

¥Linewrap

Off

¥Duplex setting

Full

¥Asynchronous format

8 data bits, no parity,

 

1 stop bit

¥Cursor

Off (if possible)

¥Display Width

80 columns

¥Display Height

24 lines (minimum)

*or any other autonomously-sent character from terminal

Screen Abbreviations

Screen diagram abbreviations used are defined in

Table 7.

Table 6. HFAC Faceplate Features

 

HFAC

Indicators

Description

 

1221051L1

and LEDs

A

CRITICAL

PWR

Indicates that power is present to the HFAC card.

L

PWR

 

 

 

 

A

MAJOR

ALARMS

Critical (red) ...... Indicates that a critical alarm condition is present.

R

M

MINOR

ACO

 

S

 

Major (red) ........ Indicates that a major alarm condition is present.

 

 

 

 

 

 

SHELF ADDRESS

Minor (yellow) ... Indicates that a minor alarm condition is present.

 

 

 

ACO ................. Alarm cut off. Indicates that the audible portion of an

 

 

 

alarm has been terminated.

CRAFT INTERFACE

 

 

 

 

SHELF

The shelf address is indicated using two 7-segment LED displays. The

R

 

ADDRESS

address is programmed using the switches described in subsection 2 and

 

 

tables A and B; or using the Options Setup screen (see Figure 11).

S

 

 

2

 

 

 

3

 

Button

A single momentary push-button provided to operate the alarm cut off

2

 

 

 

ACO

function. When the button is present, the audible portion of an active

 

0.25 AMP

alarm is silenced. The condition of the alarm itself is not affected.

 

 

 

 

 

Fuse

This 0.25 -amp fuse is provided to protect the card from power-related

 

 

 

failures. The fuse is a BUSS BMT-0.25, or equivalent. If the fuse opens, a

 

 

 

fuse alarm is generated as described in subsection 2. The fuse has a visual

 

 

 

tripped indicators. When the metal tab (visible through the cover) flips up,

 

 

 

the fuse has opened.

 

 

RS232

A faceplate-mounted DB9 connector which supplies an RS232 interface

 

 

 

for connection to a controlling terminal. Refer to subsection 5.

61221051L1-5A

61221051L1-5, Issue 1

7

Page 7
Image 7
ADTRAN E220 HFAC HDSL2 specifications Control Port Operation, Screen Abbreviations, Hfac Faceplate Features