ADTRAN E220 HFAC HDSL2 specifications Alarm Status Screen, Alarm History Screen

Models: E220 HFAC HDSL E220 HFAC HDSL2

1 20
Download 20 pages 53.58 Kb
Page 14
Image 14

Alarm Status Screen

Selection of item 3 from the Main Menu presents the Alarm Status Screen, Figure 14. This screen is a composite display of all current alarms for each of the 13 slots. Alarm types are indicated by the number 1 for Critical, 2 for Major, and 3 for Minor alarms.

A capital A indicates the alarm is current while a trailing * indicates the alarm cutoff has been exercised. ES or SES indicates the programmed threshold has been exceeded, resulting in an alarm. The position of the alarm indicator codes in the screen matrix indicates

both the alarm location and slot number.

Alarm History Screen

The Alarm History Summary Screen (Figure 15) can be accessed from the Alarm Status Screen by pressing H. This screen provides a time and date stamp for up to 100 alarm events. These events include alarm initiation and alarm clear. For convenience, a user marker can be invoked by pressing X. This produces a highly visible marking point so that subsequent alarm events can be easily distinguished from older ones.

11/23/99

00:16:44

 

 

ALARM STATUS

 

 

 

SHELF ADDRESS

= 00

 

 

 

 

 

 

 

 

B/ HTUC

[ HTUC ]

[ HRE1 ]

[ HRE2 ]

HTUR

 

ACTIVE SHELF ALARMS

SLOT UAS FUS COM SIG

LP1 LP2

LP1

 

LP2

LP1 LP2

SIG

 

-------------------

 

 

--------------------- --------- --------- --------- ----

 

CRITICAL - YES

 

1:

--- --- --- ----

---- ----

----

----

---- ----

----

 

MAJOR

 

 

- NO

 

2:

--- --- --- ----

---- ----

----

----

---- ----

----

 

MINOR

 

 

- NO

 

3:

--- --- --- ----

---- ----

----

----

---- ----

----

 

 

 

 

 

 

4:

--- --- --- ----

---- ----

----

----

---- ----

----

 

DEFAULT ALARM TRIGGERS

5:

1A --- --- ---

---- ---- ----

----

---- ----

----

 

----------------------

 

 

 

6:

--- --- --- ----

---- ----

----

----

---- ----

----

 

CRIT: 6-13 HTU-C FUSES

7:

--- --- 1C ----

---- ----

----

----

---- ----

----

 

 

UAS THRESHOLD

 

8:

--- --- --- ----

---- ----

----

----

---- ----

----

 

 

HCOT-CTL FUSE

 

9:

1A --- --- ----

---- ----

----

----

---- ----

----

 

 

COMM LINK LOSS

10:

1A --- --- ----

---- ----

----

----

---- ----

----

 

 

HFAC FUSE

11:

--- --- --- ----

---- ----

----

----

---- ----

----

 

 

 

 

 

12:

1A --- --- ----

---- ----

----

----

---- ----

----

 

MAJ:

1-5 HTU-C FUSES

13:

1A --- --- ----

---- ----

----

----

---- ----

----

 

 

ES

THRESHOLD

 

 

 

 

 

 

 

 

 

 

 

 

SES THRESHOLD

 

1

= CRIT, 2 = MAJ, 3 = MIN,

A = UAS OR FUSE ALARM,

 

 

 

 

 

 

B = BER ALARM ON PROTECTED CIRCUIT,

 

C = COMM ALARM,

 

MIN:

NONE

 

E/S = ES/SES THRESHOLD ALARM,

* = ALARM CUTOFF (ACO)

 

 

 

 

PRESS : “C”

- alarm cutoff,

“H” - alarm history,

“M”

- main menu

 

 

 

 

 

Figure 14. Alarm Status Summary Screen

 

 

 

 

 

 

 

 

08/08/70

17:51:59 CRITICAL

-UAS THRESHOLD CROSSING AT HTU-R

LP1, SLOT 10.

 

 

08/08/70

17:51:59 CRITICAL

-UAS THRESHOLD CROSSING AT HTU-R

LP2, SLOT 10.

 

 

08/08/70

17:52:09 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP1, SLOT 5.

 

 

08/08/70

17:52:09 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 5.

 

 

08/08/70

17:52:34 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP1, SLOT 9.

 

 

08/08/70

17:52:34 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 9.

 

 

08/08/70

17:52:36 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP1, SLOT 10.

 

 

08/08/70

17:52:36 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 10.

 

 

08/08/70

17:52:36 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-R

LP1, SLOT 10.

 

 

08/08/70

17:52:36 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-R

LP2, SLOT 10.

 

 

08/08/70

17:52:41 *CLEARED* -LOSS OF COMMUNICATION WITH SLOT

12.

 

 

 

08/08/70

17:52:42 CRITICAL

-LOSS OF COMMUNICATION WITH SLOT

12.

 

 

 

08/08/70

17:52:43 *CLEARED* -LOSS OF COMMUNICATION WITH SLOT

12.

 

 

 

08/08/70

17:54:00 CRITICAL

-UAS THRESHOLD CROSSING AT HTU-C

LP1, SLOT 12.

 

 

08/08/70

17:54:00 CRITICAL

-UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 12.

 

 

08/08/70

17:55:04 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP1, SLOT 7.

 

 

08/08/70

17:55:04 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 7.

 

 

08/08/70

17:55:05 CRITICAL

-UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 7.

 

 

08/08/70

17:55:07 CRITICAL

-LOSS OF COMMUNICATION WITH SLOT

7.

 

 

 

08/08/70

17:55:07 *CLEARED* -UAS THRESHOLD CROSSING AT HTU-C

LP2, SLOT 7.

 

 

----------------------------------------------------------------------------

 

 

PRESS:

 

 

 

 

 

 

ALARM HISTORY

PAGE 3 OF 5

 

 

1 TO 5 -

Select Page,

“X” - Set Marker

11/23/99

00:18:37

 

 

“P” -

Prev Screen,

“M” - Main Menu

SHELF ADDRESS = 00

 

Figure 15. Alarm History Screen

14

61221051L1-5, Issue 1

61221051L1-5A

Page 14
Image 14
ADTRAN E220 HFAC HDSL2 specifications Alarm Status Screen, Alarm History Screen