AEG 86810 manual Connecting to the water supply, Permitted water pressure, Water inlet

Models: 86810

1 48
Download 48 pages 60.57 Kb
Page 40
Image 40

1WARNING! Repairs to electrical appliances must only be carried out by trained personnel. Improper repairs may lead to serious risks for the us- er.

Connecting to the water supply

Permitted water pressure

The water pressure must be at least 1 bar (=10N/cm2 =0.1MPa), and may be a maximum of 10bar (=100N/cm2 =1MPa).

If more than 10bar: Connect a pressure reduction valve.

If less than 1bar: Disconnect the appliance end of the inlet hose from the solenoid inlet valve and remove the flow meter. (In addition re- move the filter using pointed pliers and take out the rubber gasket behind it.) Replace the filter.

Water inlet

Attention!

An inlet hose is supplied and can be found inside the machine drum.

Do not use the hose from your previous machine to connect to the water supply.

This appliance must be connected to a cold water supply.

1.Open the porthole and extract the inlet hose.

2.Connect the hose with the angled connection to the machine.

Important!

Do not place the inlet hose down- wards. Angle the hose to the left or right depending on the position of your water tap.

3. Set the hose correctly by loosening the ring nut. After positioning the inlet hose, be sure to tighten the ring nut again to prevent leaks.