Installation Instructions
Electrical Connection
The oven is designed to be connected to
The oven has an easily accessible terminal block which is marked as follows.
Letter L | - | Live terminal |
Letter N | - | Neutral terminal |
or E | - | Earth terminal |
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical supply must com- ply to the specifications given below..
Connection via | Min. size | Cable/Flex | Fuse | |
Cable/Flex | type | |||
|
| |||
|
|
|
| |
Cooker control | 6mm2 | PVC/PVC twin | 20A | |
circuit | and earth | |||
|
| |||
|
|
|
|
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm bet- ween the switch contacts and of a type suitable for the required load in compliance with the current rules.
The switch must not break the yellow and green earth cable at any point.
Important
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and the dome- stic installation can support the load, and that the power supply is pro- perly earthed.
The manufacturer disclaims any responsibility should these safety mea- sures not be carried out.