AEG B 4100 operating instructions Electrical Connection, This Oven Must Be Earthed

Models: B 4100

1 60
Download 60 pages 3.03 Kb
Page 58
Image 58
Electrical Connection

Installation Instructions

Electrical Connection

The oven is designed to be connected to 230-240V (50Hz) electricity supply

The oven has an easily accessible terminal block which is marked as follows.

Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must com- ply to the specifications given below..

Connection via

Min. size

Cable/Flex

Fuse

Cable/Flex

type

 

 

 

 

 

 

Cooker control

6mm2

PVC/PVC twin

20A

circuit

and earth

 

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm bet- ween the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the dome- stic installation can support the load, and that the power supply is pro- perly earthed.

The manufacturer disclaims any responsibility should these safety mea- sures not be carried out.

58

Page 58
Image 58
AEG B 4100 operating instructions Electrical Connection, This Oven Must Be Earthed